Technical Data

Technical Data

Category

Data

Maximum Working Fluid Pressure . . . . . . . . . . . . . . . . . .

Maximum Working Air Pressure . . . . . . . . . . . . . . . . . . . .

Maximum Gun Inlet Air Pressure for HVLP Operation . . .

Maximum Working Fluid Temperature . . . . . . . . . . . . . . .

Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gun Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

*Sound Pressure at 20 psi (140 kPa, 1.4 bar) . . . . . . . . .

*Sound Pressure at 100 psi (0.7 kPa, 7 bar) . . . . . . . . . .

*Sound Power at 20 psi (140 kPa, 1.4 bar) . . . . . . . . . . .

*Sound Power at 100 psi (0.7 kPa, 7 bar) . . . . . . . . . . . .

Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model G15: 1500 psi (10 MPa, 105 bar)

Model G40: 4000 psi (28 MPa, 280 bar)

100 psi (0.7 MPa, 7 bar)

14 psi (0.098 MPa, 0.98 bar)

110°F (43°C) 1/4-18 npsm

1/4-18 npsm (R1/4-19) compound male thread 16 oz (450 grams)

66.9dB(A)

80.0dB(A)

76.8dB(A)

89.9dB(A)

Stainless Steel, Carbide, Ultra High Molecular Weight Polyethylene, Engineered Plastic, PTFE, Nylon, Fluoro- elastomer

*All readings were taken with the fan valve fully closed (full fan size), at 20 psi (140 kPa, 1.4 bar) and 100 psi (0.7 kPa, 7 bar), and at the assumed operator position. Sound Power was tested to ISO 9614-2.

 

12

 

10

 

8

Air Flow

6

(SCFM)

 

 

4

 

2

 

0

Air Flow, Standard Air Cap

10.6

8.6

6.4

5.8

4.2

4.6

3.8

2.6

0

10

20

30

40

50

 

 

Gun Inlet Pressure (PSI)

 

 

Fan Valve Open

Fan Valve Closed

3A0149E

39

Page 39
Image 39
Graco 3A0149E important safety instructions Technical Data, Category Data, Gun Inlet Pressure PSI