Installation

Installation

The agitator speed controller fits the following Graco pneumatic rotary motors:

Motor Part No.

101140

16A871

101388

111310

NOTE: Before installing, ensure that the agitator air motor has at least 5 in. (12.7 cm) of vertical clearance and 4 in. (10.2 cm) of horizontal clearance in all directions around it.

NOTE: If you are using an air line lubricator, install it in the air line upstream of the speed controller.

1.Remove the air motor top cap (A) and needle valve (B) using the multi-function wrench (26). Store these parts in a safe place; they will be needed if the speed controller is ever removed.

2.Install the push-to-connect air tube connector

(21)in place of the needle valve.

TI17256a-1

3.Screw the compression nut (24) onto the flange connector (23) finger-tight. Place the connector assembly (23, 24) onto the exposed shaft of the air motor, flange connector side down.

TI17254a-1

TI17257a-1