GunOverview
Error ErrorErrorDisplay DisplayDisplay
IftheSmartmodulelosescommunicationwith
thepowersupply,theErrordisplayappears,the
Hzindicatorturnsred,andtheSmartmoduleis
disabled.SeeFig.3,andTable1onpage10.
ThiscanoccurinOperatingModeorDiagnostic
Mode.SeeElectricalTroubleshooting,page35.
CommunicationmustberestoredtomaketheSmart
modulefunctional.
NOTE: NOTE:
NOTE:Ittakes8secondsfortheErrordisplayto
appear.Ifthegunhasbeendisassembled,wait8
secondsbeforesprayingtoensurethatanError
conditionhasnotoccurred.
NOTE: NOTE:
NOTE:Ifthereisnopowertothegun,theError
displaywillnotappear.
Figure3ErrorDisplay
Adjusting AdjustingAdjustingthe thetheLow LowLowVoltage VoltageVoltageSetting SettingSetting
Thelowvoltagesettingisuseradjustable.Toaccess
thelowvoltagesettingscreenwheninOperating
Mode,presstheLOSETbutton(LS)momentarily.
Thescreenwilldisplaythecurrentlowvoltage
setting.SeeFig.4,andTable1onpage10.The
possiblerangesare:
85kVguns:40–85kV
60kVguns:30–60kV
SettheVoltageAdjustmentswitch(VA)toLO.Press
theLOSETbuttonrepeatedlytoincreasethesetting
inincrementsof5.Whenthedisplayreachesthe
maximumsettingitwillreturntotheminimumsetting
foryourgun.Continuepressingthebuttonuntilyou
reachthedesiredsetting.
NOTE: NOTE:
NOTE:After2secondsofinactivitythedisplaywill
returntotheOperatingScreen.
NOTE: NOTE:
NOTE:Thelowvoltagesettingmaybelocked.See
LockSymbol,page10.
Figure4LowVoltageSettingScreen(Unlocked)
Lock LockLockSymbol SymbolSymbol
Thelowvoltagesettingmaybelocked.Whenlocked,
animage(LK)appearsonthescreen.SeeFig.5,
andTable1onpage10.
WheninHImode,thelowvoltagesettingisalways always
always
locked.ThelocksymbolwillappearwhentheLO
SETbuttonispressed.
WheninLOmode,thelocksymbolwill
only only
onlyappearifthelockisenabled.See
LowVoltageLockScreen,page14,tolockor
unlockthelowvoltagesetting.
Figure5LowVoltageSettingScreen(Locked)
10 3A2494D