GunOverview
Diagnostic DiagnosticDiagnosticMode ModeModeDiagnosticModeincludesfourscreenswhichdisplay
gundata:
•Voltage(kiloVolts)Screen
•Current(microAmperes)Screen
•AlternatorSpeed(Hertz)Screen
•LowVoltageLockScreen
NOTE: NOTE:
NOTE:YoumustbeinOperatingModetoadjustthe
lowvoltagesetting;thesettingisnotadjustablein
DiagnosticMode.However,thevoltageadjustment
switch(VA)canbesettoHIorLOinOperatingMode
andinDiagnosticMode.
ToenterDiagnosticMode,pressandholdtheLOSET
(LS)buttonforapproximately5seconds.Thedisplay
willgototheVoltage(kiloVolts)Screen,page13.
Toadvancetothenextscreen,presstheLOSET
buttonagain.
ToexitDiagnosticMode,pressandholdtheLOSET
buttonforapproximately5seconds.Thescreenwill
returntoOperatingMode.
NOTE: NOTE:
NOTE:IfthegunisdetriggeredwhileinDiagnostic
Mode,thelastscreenviewedwillbedisplayedwhen
thegunisretriggered.
NOTE: NOTE:
NOTE:DiagnosticModecannotbeexited
fromtheLowVoltageLockScreen.See
LowVoltageLockScreen,page14fordetails.
Voltage VoltageVoltage(kiloVolts) (kiloVolts)(kiloVolts)Screen ScreenScreenTheVoltage(kiloVolts)Screenistherstscreento
appearafterenteringDiagnosticMode.SeeFig.6,
andTable1onpage10.Toenterthisscreen,press
andholdtheLOSETbuttonforapproximately5
secondswhileintheOperatingMode.
Thisscreendisplaysthesprayingvoltageofthe
gunasanumber(kV),roundedtothenearest5kV.
ThetwotoprightLEDs(VI)ofthedisplaypanel
light,indicatingthattheVoltage(kiloVolts)Screen
isdisplayed.Thedisplayisareadoutandcannot
bechanged.
PresstheLOSETbuttontoadvancetothe
Current(microAmperes)Screen,page13.Press
andholdforapproximately5secondstoreturnto
OperatingMode.
Figure6Voltage(kiloVolts)Screen
Current CurrentCurrent(microAmperes) (microAmperes)(microAmperes)Screen ScreenScreenTheCurrent(microAmperes)Screenisthesecond
screenintheDiagnosticMode.SeeFig.7,andTable
1onpage10.Toenterthisscreen,presstheLO
SETbuttonwhileintheVoltage(kiloVolts)Screen.
Thisscreendisplaysthesprayingcurrentofthegun
asanumber(uA),roundedtothenearest5uA.The
twobottomrightLEDs(CI)ofthedisplaypanellight,
indicatingthattheCurrent(microAmperes)Screen
isdisplayed.Thedisplayisareadoutandcannot
bechanged.
PresstheLOSETbuttontoadvancetothe
AlternatorSpeed(Hertz)Screen,page14.Press
andholdforapproximately5secondstoreturnto
OperatingMode.
Figure7Current(microAmperes)Screen
3A2494D 13