Repair
Fluid Fluid
FluidPacking Packing
PackingRod Rod
RodRemoval Removal
Removal
1.SeePreparetheGunforService,page37.
2.Removetheaircapanduidnozzle.See
AirCapandNozzleReplacement,page38.
3.Removetheelectrode.See
ElectrodeReplacement,page39.
4.Loosenthetriggerscrews(13)andremovethe
trigger(12).
5.Removethepackingrod(2),usingthemulti-tool
(41).Removethespring(17).
6.Checkallpartsforwearordamageandreplace
ifnecessary.
Figure22FluidPackingRodRemoval
Packing Packing
PackingRod Rod
RodRepair Repair
Repair
NOTE: NOTE:
NOTE:Youmayreplacethepackingrodasindividual
partsorasanassembly.
Adjust Adjust
Adjustthe the
theAir Air
AirFlow Flow
FlowLead Lead
Leadand and
andLag Lag
Lag
NOTE: NOTE:
NOTE:Thegunbeginsemittingairbeforetheuid
isdischargedandtheuidstopsbeforetheairow
stops.Thepackingrodassemblyispre-adjustedat
thefactoryforproperairleadandlag.Adjustonly
ifnecessary,asfollows.
1.Removethespring(17)fromthenut(2k).
2.Useahexwrenchtoholdtheendofthepacking
rod.Turnbothadjustmentnuts(2j,2k)outto
increasethelead/lagtimefortheairow.The
recommendedadjustmentisonehalfturnand
notmorethanonefullturn.
3.Tightenthenutstogethertoxtheminthenew
position.
40 3A2494D