NOTICE

Overtightening the spray tip (5) can damage the tip and cause poor spray performance.

5.Install the spray tip (5) and tighten using the wrench (6). When tightening, only grip the end of the wrench with your fingers. Do not grip the wrench cross-arms (E).

Installation

6.Adjust the spray pattern as explained in the Gun Setup Checklist of your Pro Xp gun manual.

NOTE: The recommended spraying distance from the front of the gun to the object being sprayed is 8–12 in. (203–305 mm). Round spray tips emit a soft pattern. If the gun is too far from the object, the floating charged particles may be attracted to the gun or operator instead of to the grounded object.

NOTE: See Round Spray Tips, page 5 , for fluid flow information. See

Spray Pattern Troubleshooting, page 5 , to correct spray pattern problems.

NOTE: If the spray tip clogs, stop spraying immediately and relieve pressure. Clean the tip as explained in your Pro Xp gun manual. To help reduce spray tip clogging, clean or replace the fluid filter supplied with the gun.

3A2499B

3

Page 3
Image 3
Graco 24N319, 3A2499B important safety instructions Installation