Component Identification
GroundingAccessories
Bleed-type master air valve
See FIG. 2. Verify that the ground screw (GS) is attached and tightened securely to the air motor. Con- nect the other end of the ground wire (U) to a true earth ground.
Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing or moving parts.
GS U
FIG. 2: Ground wire
ti12914a
•Required in your system to relieve air trapped between it and the air motor when the valve is closed.
•Be sure the valve is easily accessible from the pump and located downstream from the air regula- tor.
Air regulator
Adjusts air pressure to the motor and fluid outlet pres- sure of pump. Locate it close to the pump. Install a gauge to read air pressure.
Air filter
Removes harmful dirt and moisture from compressed air supply.