Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

Herbicide leaking in motor mount.

Faulty or damaged motor shaft seal

Replace shaft seal

 

(1h).

 

 

 

 

 

Operating pump extended time with

Do not exceed 5 minutes of operation

 

nozzle closed.

with nozzle closed.

 

 

 

 

Motor shaft worn.

Replace motor if shaft has groove

 

 

worn in seal area.

 

 

 

Motor overheating.

Gears (1c/10a) binding.

Check to make sure gears turn freely

 

 

on shaft.

 

 

 

 

Operating pump extended time with

Do not exceed 5 minutes of operation

 

nozzle closed.

with nozzle closed.

 

 

 

 

Clogged inlet strainer (3b).

Clean or replace, see Maintenance,

 

 

page 6.

 

 

 

 

Clogged suction tube, hose, or

Inspect and clean if required.

 

nozzle.

 

 

 

 

 

Operating pump more than 30 min-

Limit operation to 30 minutes per

 

utes continuous duty.

hour.

 

 

 

Switch will not turn pump on.

Blown fuse.

Replace fuse. 20 amp automotive

 

 

fuse (Littelfuse ATO 257020 or

 

 

Bussman ATC-20).

 

 

 

 

Electrical problem.

Check that supply voltage is proper

 

 

and getting to pump.

 

 

 

 

Defective switch (8e).

Check and replace if defective.

 

 

 

 

Mechanical problem.

Check switch actuator cam (8c). Cam

 

 

should be actuating the switch (8e).

 

 

 

 

Damaged or defective motor.

Check motor, replace if damaged or

 

 

defective.

 

 

 

311628C

9

Page 9
Image 9
Graco Model 260408, Model 260409, Model 260410 Problem, Cause, Solution, Herbicide leaking in motor mount