| Troubleshooting |
|
|
|
Problem | Cause | Solution |
|
|
|
|
|
|
Herbicide leaking in motor mount. | Faulty or damaged motor shaft seal | Replace shaft seal |
| (1h). |
|
|
|
|
| Operating pump extended time with | Do not exceed 5 minutes of operation |
| nozzle closed. | with nozzle closed. |
|
|
|
| Motor shaft worn. | Replace motor if shaft has groove |
|
| worn in seal area. |
|
|
|
Motor overheating. | Gears (1c/10a) binding. | Check to make sure gears turn freely |
|
| on shaft. |
|
|
|
| Operating pump extended time with | Do not exceed 5 minutes of operation |
| nozzle closed. | with nozzle closed. |
|
|
|
| Clogged inlet strainer (3b). | Clean or replace, see Maintenance, |
|
| page 6. |
|
|
|
| Clogged suction tube, hose, or | Inspect and clean if required. |
| nozzle. |
|
|
|
|
| Operating pump more than 30 min- | Limit operation to 30 minutes per |
| utes continuous duty. | hour. |
|
|
|
Switch will not turn pump on. | Blown fuse. | Replace fuse. 20 amp automotive |
|
| fuse (Littelfuse ATO 257020 or |
|
| Bussman |
|
|
|
| Electrical problem. | Check that supply voltage is proper |
|
| and getting to pump. |
|
|
|
| Defective switch (8e). | Check and replace if defective. |
|
|
|
| Mechanical problem. | Check switch actuator cam (8c). Cam |
|
| should be actuating the switch (8e). |
|
|
|
| Damaged or defective motor. | Check motor, replace if damaged or |
|
| defective. |
|
|
|
311628C | 9 |