MAINTAIN FIRM

10.Point the gun into the metal pail and hold a metal part of the gun firmly against the pail. See Fig 7.

..-----~WARNING-----..,

To reduce the risk of static sparking, which can cause fire or explosion, always hold a metal part of the gun firmly against a grounded metal pail when flushing. This also reduces splashing.

MAINTAIN FIRM

METAL TO METAL

CONTACT WHEN

FLUSHING

Fig 7 -----------------

11.Disengage the gun safety latch and squeeze the gun trigger. At the same time, slowly turn the pressure control knob clockwise just enough to start the pump. See Fig 5.

12.A"ow the pump to operate until clean solvent comes from the gun.

13.Release the trigger and engage the gun safety latch.

14.If you are going to start spraying, place the pump or accessory suction tube into the supply container. Release the gun safety latch and trigger the gun into another empty, metal container, holding a metal part of the gun firmly against the metal pail, and force the solvent from the pump and hose. Engage the gun safety latch until you are ready to prime the pump (see Step 3, page 9).

15.If you are going to store the sprayer, remove the accessory suction tube or pump from the sol- vent pail, holding a metal part of the gun firmly against the metal pail, and force the solvent from the pump and hose. Engage the gun safety latch. Refer to the "Storage" procedure in the section "When To Flush", see page 6.

16.Whenever you shut off the sprayer, follow the Pressure Relief Procedure Warning, on page 2 or 8.

307-293 7