Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

A strong hose recoil occurs

The unit is not on a level surface.

Place the unit on a level surface. If this

frequently when the blast

 

is impossible, the Auto-Vent must be on

control switch is engaged.

 

the higher side of the unit.

 

The initial pot pressure is not set

Confirm that the auto-vent valve is

 

correctly.

working and set initial pot pressure 30

 

 

psi (2.0 bar, 0.20 MPa) above the blast

 

 

pressure.

 

The Auto-Vent is malfunctioning.

Perform auto-vent clean-

 

 

ing procedure (see

 

 

Cleaning the Auto-Vent Valve, page 31).

 

The diaphragm needs to be

Perform the diaphragm

 

flushed.

flush procedure (see

 

 

Flushing the Diaphragm Valve, page 29).

 

 

If flushing does not solve the problem, see

 

 

Repairing the Diaphragm Valve, page 30.