Replacing the DataTrak Battery

Repair

Replacing the DataTrak Battery

FIRE AND EXPLOSION HAZARD

To reduce the risk of fire and explosion, the battery must be replaced in a non-hazardous location.

Use only an approved replacement battery (see table). Use of an unapproved battery will void Graco’s warranty.

Replace Battery

1.Unscrew cable from the back of the reed switch assembly.

2.Remove the cable from the two cable clips.

3.Remove the DataTrak module from the bracket. Take the module and attached cable to a non-hazardous location.

4.Remove the two screws on the back of the module to access the battery.

5.Disconnect the used battery and replace it with an approved battery.

Approved Batteries

Energizer alkaline #522

Varta alkaline #4922

Ultralife lithium #U9VL

Duracell alkaline #MN1604