Pressure Control

Control Board Diagnostics

1.Fig. 15. Remove five screws (307) and cover (322).

2.Start sprayer.

LED

SPRAYER OPERATION

BLINKS

 

3.Turn ON/OFF switch ON.

4.Observe LED operation and reference following table:

INDICATES

WHAT TO DO

 

 

Two times

Sprayer shuts down and LED contin-

Run away pressure.

repeatedly

ues to blink two times repeatedly

Pressure greater than

 

 

4500 psi (310 bar, 31

 

 

MPa).

 

 

 

Three

Sprayer shuts down and LED contin-

Pressure transducer is

times re-

ues to blink three times repeatedly

faulty or missing

peatedly

 

 

 

 

 

1.Check pressure transducer con- nection at control board

2.Replace pressure transducer

3.Replace control board

1.Check pressure transducer con- nection at control board

2.Replace pressure transducer

3.Replace control board

Four times

Sprayer shuts down and LED contin-

Generator voltage is

repeatedly

ues to blink four times repeatedly

low

 

 

 

1.Increase engine throttle

2.Check wiring connections

3.Service Honda engine alternator

Five times

Sprayer shuts down and LED contin-

High clutch current

repeatedly

ues to blink five times repeatedly

 

 

 

 

1.Check clutch 5-pin bulkhead con- nector. Clean contacts.

2.Measure 1.7 ±0.2Ω across clutch field at 70_F

3.Replace clutch field assembly

Six times

Sprayer shuts down and LED contin-

High clutch temperature

1.

If clutch is new, let sprayer cool

repeatedly

ues to blink six times repeatedly

 

 

down and then restart

 

 

 

2.

Inspect clutch. Replace clutch if

 

 

 

 

there is excessive wear.

 

 

 

3.

Remove pump pin, separate pin-

 

 

 

 

ion housing from clutch housing.

 

 

 

 

Rotate rotor clockwise to check

 

 

 

 

for excessive drag.

14 ￿08870