Graco Inc 311796B important safety instructions Fire and Explosion Hazard

Models: 311796B

1 32
Download 32 pages 5.32 Kb
Page 4
Image 4

Warning

Warning

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

• Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

ELECTRIC SHOCK HAZARD

Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power cord before servicing equipment.

Use only grounded electrical outlets.

Use only 3-wire extension cords.

Ensure ground prongs are intact on sprayer and extension cords.

Do not expose to rain. Store indoors.

4

311796B

Page 4
Image 4
Graco Inc 311796B important safety instructions Fire and Explosion Hazard

311796B specifications

Graco Inc. is renowned for its innovative solutions in the field of fluid management and handling. Among its impressive portfolio of products, the Graco Inc. 311796B stands out as a premier choice for professionals in various industries. This air-operated diaphragm pump is engineered to provide reliable performance and versatility, making it an essential tool for tasks requiring precise fluid transfer.

One of the prominent features of the Graco Inc. 311796B is its robust construction. Built with high-quality materials, this pump is designed to withstand demanding environments, ensuring longevity and minimal maintenance. The pump's design incorporates a lightweight yet durable structure, facilitating ease of transport and installation.

The 311796B model showcases advanced technology, including an innovative air valve design that enhances efficiency and reliability. This technology allows for smooth operation, reducing the risk of stalling during fluid transfer. Additionally, the pump offers adjustable flow rates, which enable users to customize the pumping process according to their specific needs. This adaptability makes the Graco 311796B suitable for a wide range of applications, from industrial to commercial settings.

Another key characteristic of the Graco 311796B is its compatibility with various fluids. Whether handling water-based, solvent-based, or viscous liquids, this pump performs exceptionally well, ensuring precise and consistent flow. The materials used in the pump's construction are resistant to corrosion, making it ideal for use with harsh chemicals.

Moreover, the Graco Inc. 311796B is designed for ease of maintenance. Its simple assembly and disassembly processes allow users to perform routine checks and repairs quickly. This user-friendly design minimizes downtime, keeping operations running smoothly and efficiently.

In summary, Graco Inc. 311796B represents a blend of durability, advanced technology, and versatility. With its robust construction, efficient air valve design, adjustable flow rates, and chemical compatibility, it serves as a reliable solution for fluid management needs across diverse industries. Whether for professionals in manufacturing, automotive, or construction, the Graco 311796B is a top choice that promises reliability and performance. As industries continue to evolve, products like the Graco 311796B will remain integral to enhancing productivity and ensuring seamless operations.