Graco Inc G30W82, 313255F, G28C18 Diagnostic Codes, Symbol Code Code Name Diagnosis Cause

Models: G30W82 313255F G28C18

1 34
Download 34 pages 14.65 Kb
Page 22
Image 22

DataTrak Operation

Table 1:Diagnostic Codes

 

Symbol

Code

Code Name

Diagnosis

 

Cause

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Runaway

Pump running faster

Increased air pressure.

 

 

 

 

 

 

(DataTrak only)

than set runaway

Increased fluid output.

 

 

 

 

 

 

 

limit.

Exhausted fluid supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-1

Diving Up

Leak during

Worn piston valve or packings.

 

 

 

 

 

 

 

upstroke.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-2

Diving Down

Leak during

Worn intake valve.

 

 

 

 

 

 

 

downstroke.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-3

Low Battery

Battery voltage too

Low battery. Replace battery; see

 

 

 

 

 

 

 

low to stop runaway.

page 23.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-4

Service Component

Problem with

Damaged solenoid.

 

 

 

 

 

 

1

stopping runaway.

Damaged valve carriage.

 

 

 

 

 

 

(units with runaway

 

• Runaway (RT, FIG. 8) protection

 

 

 

 

 

 

protection only)

 

 

may be enabled with pump that

 

 

 

 

 

 

 

 

 

is not equipped with a runaway

 

 

 

 

 

 

 

 

 

solenoid valve. Enter setup

 

 

 

 

 

 

 

 

 

screen and disable runaway pro-

 

 

 

 

 

 

 

 

 

tection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-4

Disconnected

Solenoid is

Solenoid unplugged.

 

 

 

 

 

 

Solenoid

disconnected.

Damaged solenoid wires.

 

 

 

 

 

 

(units with runaway

 

 

 

 

 

 

 

 

 

Solenoid is not

• Bracket and solenoid not tight

 

 

 

 

 

 

protection only)

 

 

 

 

 

 

engaging piston cup

 

against air valve housing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(112).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-5

Service Component

Problem with

Sensors unplugged.

 

 

 

 

 

 

2

sensing valve

Sensors mounted incorrectly.

 

 

 

 

 

 

 

movement.

Damaged sensors.

 

 

 

 

 

 

 

 

Damaged valve carriage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E-6

Blown Fuse

Fuse is blown.

• Faulty solenoid or solenoid wir-

 

 

 

 

 

 

 

Replace fuse; see

 

ing.

 

 

 

 

 

 

 

page 23.

Extreme temperatures (above

 

 

 

 

 

 

 

 

 

140°F [60°C]).

 

 

 

 

 

 

 

 

• Runaway (RT, FIG. 8) protection

 

 

 

 

 

 

 

 

 

may be enabled with pump that

 

 

 

 

 

 

 

 

 

is not equipped with a runaway

 

 

 

 

 

 

 

 

 

solenoid valve. Enter setup

 

 

 

 

 

 

 

 

 

screen and disable runaway pro-

 

 

 

 

 

 

 

 

 

tection.

 

 

 

 

 

 

 

 

 

 

22

313255F

Page 22
Image 22
Graco Inc G30W82, 313255F, G28C18 important safety instructions Diagnostic Codes, Symbol Code Code Name Diagnosis Cause