DataTrak Operation

DataTrak Operation

NOTE: The display (AE) will turn off after 1 minute to save battery life. Press any key to wake up the display.

NOTICE

To prevent damage to the soft key buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails.

Setup Mode

1.See FIG. 8. Press and hold for 5 seconds until Setup menu appears.

2.To enter settings for runaway (if equipped), lower size, and flow rate units, and to enable runaway, E1,

E2, and E5 error options, press to change the

value, then to save the value and move the cur- sor to the next data field. See page 22 for a descrip- tion of E1, E2, and E5 error codes.

NOTE: Graco recommends setting runaway (if

equipped) to 60 .

NOTE: When runaway, E1, E2, and E5 error options are enabled, a will appear on the setup screen.

See FIG. 8.

3.Move the cursor to the E5 error enable option field,

then press once more to exit Setup mode.

Run Mode

Runaway

NOTE: DataTrak is available with and without runaway protection. Packages with M02xxx air motors ship with- out a runaway solenoid. All other DataTrak packages are equipped with a runaway solenoid.

1.See FIG. 8. If pump runaway occurs, the runaway solenoid will actuate, stopping the pump. The LED (AD) will flash and the display (AE) will indicate a runaway condition (see Table 1). The display will cycle through six instruction screens.

2.Runaway Screens 1 and 2: To reset the runaway solenoid, close the master air valve (E). Wait for air to completely bleed off the air motor.

3.Runaway Screens 3 and 4: After the air is bled off, push the solenoid release button (J) down to reset the air valve. The button will pop back up when the air valve is repressurized.

J

ti11902a

FIG. 9. Solenoid Release Button

4.Runaway Screens 5 and 6: Press to clear the diagnostic code and reset the runaway solenoid.

5. Open master air valve (E) to restart pump.

NOTE: To disable runaway monitoring, go to setup mode and set runaway value to 0 (zero) or toggle (RT)

off (see FIG. 8).

20

313255F

Page 20
Image 20
Graco Inc G28C18, 313255F, G30W82 important safety instructions DataTrak Operation, Setup Mode, Run Mode, Runaway