Graco Inc GH2075 Flushing, Fire And Explosion Hazard, To reduce the risk of static sparking and

Models: 687327

1 38
Download 38 pages 9.01 Kb
Page 9
Image 9
To reduce the risk of static sparking and

Flushing

Manual background WARNING

FIRE AND EXPLOSION HAZARD

To reduce the risk of static sparking and

splashing when flushing, always remove the spray tip from the gun and hold a

metal part of the gun firmly to the side of a grounded metal pail.

11.Making firm metal-to-metal contact, hold the gun firmly to the side of the grounded solvent pail. Trigger the gun. At the same time, slowly turn the pressure control knob clockwise just enough to start the pump.

12.Circulate the solvent until the system is thoroughly flushed.

13.Release the trigger and engage the gun safety latch.

14.If you are going to start spraying, place the pump or suction tube into the supply container. Follow the Pressure Relief Procedure on page 10. Engage the gun safety latch until you are ready to prime the pump. See Step 3, page 9.

15.If you are going to store the sprayer, be sure your final flush is with an oil--based solvent, such as mineral spirits. Remove the suction tube or pump from the solvent pail. Follow the Pressure Relief Procedure on page 10. Engage the gun safety latch, but leave the drain valve open.

308972 9

Page 9
Image 9
Graco Inc GH2075, 687327, 687100 Flushing, Fire And Explosion Hazard, To reduce the risk of static sparking and, 308972