WARNING

HIGH PRESSURE SPRAY CAN CAUSE SERIOUSINJURY.

FOR PROFESSIONALUSE ONLY. OBSERVE ALL WARNINGS.

Read and understand all instruction manuals before operating equipment.

FLUID INJECTION HAZARD

 

 

 

 

 

 

 

General Safety

 

 

 

Pressure Relief Procedure

 

 

Thispressurewashergeneratesvery

 

high fluid

To reducethe risk of seriousbodily injury, includingfluid

pressureSprayfrom.

the gun, leaks

orruptured

injection and splashing in theeyesor

on theskin,

components can injectfluid through yourskin and into

alwaysfollowthisprocedure

whenever you

stop

your body and cause extremely serious

bodily injury

sprayingfor more than10minutes, when shuttingdown,

including theneedfor amputationAlso,.

fluid injectedor

andbefore checkingor repairingany part of the system.

splashed into the eyesor on the skin can cause serious

1.

Engagethetriggersafetylatch.

 

 

damage.

 

 

 

 

 

N N E R point the spray

gun or wand

at

anyoneat anyor

2.

Tum the sprayer off.

 

 

 

part of the body. NNER put hand or fingers over the

3.

Remove the ignition cable from the spark plug.

spray tip.

 

 

 

ALWAYS follow the Pressure Rellef Procedure, before

4.

Shut off the water supply.

 

 

cleaning or servicing any part ofthe sprayer.

5.

Disengagethetriggersafetylatch

and triggerthe

 

 

 

 

N N E R try to stop or deflect leaks with your hand or

 

gun to relieve pressure, and then engage the trigger

body.

 

 

 

 

safety latch again.

 

 

 

Be sureequipmentsafetydevicesareoperating

 

6.

Beforelong-term

(overnight)

storage

or

properly before each use.

 

 

 

transporting of the unit, disconnect the water supply

MedicalTreatment

 

 

 

 

and disconnectthe fuel supply.

 

 

 

 

 

Spray Gun Safety Devices

 

 

If any fluid appearstopenetrateyourskin,get

 

 

 

EMERGENCYMEDlCALTREATMENTATONCE.DO Be sure all gun safety devices are operating properly

NOT TREAT AS A SIMPLECUT.Tell the doctor exactly before eachuse. Do not remove ormodify any part of

what fluid was injected.thegun; thiscancauseamalfunctionandresult in sefious bodily injury.

NOTE TO PHYSICIAN: Injectionin the skin is a

 

 

 

traumatic injuv.It isImportant to treat the Injury

SAFETY LATCH: Whenever you stop spraying fora

surgically a s soon as posslble. Do not delay

moment, always set the gun safetylatchinthe engaged

treatmentto

research toxicity Toxicity is a

or "safe" position,makingthe gun inoperative. Failureto

concern with

someexotic coatings injected

properly set thesafetylatchcanresult

in accidental

directly into the bloodstream. Consultation with a

triggering of

thegun.

 

plastic surgeon or reconstructive hand surgeon

SPRAY TIP

SAFEPI: Useextreme

caution when

may be advisable.

 

 

cleaning or changing spray tips. If a spray tip clogs

 

 

whilespraying,engagethegunsafety

latch

 

 

immediately. ALWAYS follow the Pressure Relief

 

 

Procedure and then remove the spraytip to clean it,

2308-528

Page 2
Image 2
Graco Inc 800-668, 800-666 manual Fluid Injection Hazard, General Safety Pressure Relief Procedure, MedicalTreatment

800-666, 800-668 specifications

Graco Inc, a leading manufacturer in the fluid handling industry, is well-known for its innovative solutions that cater to a wide range of applications. Among its extensive product lineup, the Graco Inc 800-668 and 800-666 models stand out for their impressive features and cutting-edge technologies designed for efficiency, precision, and reliability.

The Graco 800-668 model is a heavy-duty diaphragm pump that excels in transferring a variety of fluids, including corrosive materials and viscous substances. This model is engineered with advanced materials that enhance its durability and resistance to wear, ensuring long-lasting performance even in the most demanding environments. Its robust construction allows for high flow rates and exceptional suction capabilities, making it ideal for industrial operations where efficiency is crucial.

In contrast, the Graco 800-666 model is a versatile piston pump that offers remarkable pressure output and flow consistency. This model is particularly suitable for applications requiring precise fluid dispensing and high-pressure spraying. The Graco 800-666 is equipped with a patented control technology that allows users to adjust the flow rate, ensuring precise delivery of materials. This feature significantly reduces waste and enhances productivity, a vital aspect in sectors such as automotive, aerospace, and construction.

Both models utilize Graco’s proprietary technology, ensuring optimal performance across a variety of applications. They are designed for easy maintenance, with accessible components that facilitate quick repairs and part replacements. This design consideration reduces downtime and ensures continuous operation, which is essential in an industrial setting.

In addition to their functional features, Graco 800-668 and 800-666 are engineered with safety in mind. They incorporate various safety mechanisms to prevent leaks and overpressurization, protecting both the operator and the environment. This commitment to safety is paired with ergonomic designs that enhance user comfort and reduce physical strain during operation.

Overall, Graco Inc 800-668 and 800-666 models exemplify the brand’s dedication to innovation and quality in the fluid handling industry. Their advanced features, reliability, and user-friendly design make them ideal choices for professionals seeking high-performance pump solutions for various applications. With Graco, users can expect not only superior technology but also a commitment to excellence and customer satisfaction that has solidified the brand's reputation worldwide.