Graham Field 753004, 753003 Symbols, Indications for Use, Contraindication, Safety Precautions

Models: 753004 753003

1 9
Download 9 pages 33.45 Kb
Page 3
Image 3

Lumex® AltaDyne AutoFloat

Indications for Use/Safety Precautions

2.0 Symbols

Attention, consult accompanying document

Type BF equipment

Dangerous voltage

Protective earth

3.0 Indications for Use

This device is intended to assist in treating and preventing pressure ulcers.

4.0 Contraindication

Air support treatment is not recommended when spinal stability is a concern.

5.0 Safety Precautions

Review the following SAFETY PRECAUTIONS prior to using the AltaDyne Auto FloatSystem.

DANGER

Risk of electric shock. Refer servicing to qualified service personnel.

WARNING

Disinfect the AltaDyne AutoFloat system between patient installations. Failure to disinfect may risk cross- contamination and infection.

Check patient at least every 8 hours or once per shift, to assure proper system operation.

Deflate mattress before performing CPR or CPR will be ineffective.

CAUTION

Some medical conditions may not respond to treatment of this type. Patient’s skin condition should be inspected regularly. Consult physician if any redness or skin breakdown occurs.

For grounding reliability, plug only into a properly grounded outlet.

Make certain all mattress straps are secured to the bed frame to prevent mattress from sliding and causing patient injury.

Lumex® mattresses are not intended to be AND DO NOT FUNCTION AS a patient fall safety device. SIDE RAILS MUST BE USED WITH THE LUMEX® MATTRESS TO PREVENT FALLS, unless determined unnecessary based on the facility protocol or the patient's medical needs as determined by the facility, IN WHICH CASE THE USE OF OTHER SUITABLE PATIENT SAFETY MEASURES ARE RECOMMENDED.

Use minimal layers of sheeting and incontinence pads. Too many layers between the patient’s skin and the support surface will reduce the effectiveness of the system.

Do not pull linens tightly over mattress. Tight sheets can cause “hammocking” and reduce effectiveness of treatment.

Medical Electrical Equipment requires special precautions regarding EMC and should be installed and put into service according to the EMC information provided in the accompanying documents.

Portable and RF communications equipment can affect medical electrical equipment.

Do not use in the presence of smoking materials or open flame. Air flowing through the air mattress will support combustion.

3

Page 3
Image 3
Graham Field 753004, 753003 manual Symbols, Indications for Use, Contraindication, Safety Precautions