IMPORTANT; Your Homestead patio fireplace cannot be converted to use Natural Gas. Attempting to do so is extremely hazardous and wilt also void the warranty.
Correct LP Gas Tank Use
The patio fireplace is designed for use with a standard 20 lb. Liquid Propane Gas (LP Gas) tank, not included in box. Never connect your fireplace to an LP gas tank directly without regulator that exceeds this capacity. A tank of approximately 12 inches in diameter by
The LP gas tank must be connected and marked in accordance with the specification for
1.The LP gas tank has a shutoffvalve, terminating in an LP gas supply tank valve outlet, that is compatible with type 1 tank connection device. The LP gas tank must also have a safety relief device that has a direct connection with the vapor space of the tank.
2.The tank supply system must be arranged for vapor withdrawal.
3.The LP gas tank used must have a collar to protect the tankvalve.
This patio fireplace isnot intended to be installed in or on recreational vehicles and!or boats.
Never connect an unregulated LP gas tank to your fireplace. The gas regulator assembly supplied with your fireplace is adjusted to have an outlet pressure of 11" water column(W.C.) for connection to an LP gas tank.
Only use the regulator with hose assembly supplied with your fireplace. Replacement regulator with hose assembly must be those specified by manufacturer.
Have your LP gas tank filled by a reputable propane gas dealer and visually inspected and
Never fill the gas tank beyond 80 percent full. Have your propane gas dealer check the release valve
after every filling to ensure that it remains free of defects.
Always keep LP gas tanks in upright position. Do not store(or use) gasoline or other flammable vapors and liquids in vicinity of this fireplace.
LP gas tanks not connected for use must NOT be stored inside of fireplace or in the vicinity of this or any other gas appliance.
Do not subject the LP gas tank to excessive heat. Never store an LP gas tank in the garage or other indoor location. Always disconnect the LP gas tank first and store it safety outside.
LP gas tanks must be stored outdoors in a well- ventilated area and out of the reach of children.
Disconnected LP gas tanks must not be stored in a building, garage or any other enclosed area.
When your fireplace is not in use the gas must be turned off at the gas tank.
The regulator with hose assembly can be seen when you open the doors. It should be inspected before each use of the fireplace. If there is excessive wear or any abrasions, or if the hose is
cut, it must be replaced prior to the fireplace being used.
Keep the gas regulator hose away from hot surface. Avoid unnecessary twisting of hose. Visually inspect hose prior to each use for cuts, cracks, excessive wear or other damage. If the hose appears damaged do not use the fireplace. Call
Never allow children to play near your fireplace.
4