B. Turning the fireplace off

Press ON/OFF button to turn fireplace off.

Close valve on gas tank and close Door.

Note: If the fireplace does not turn off by pressing the ON/OFF button, close the manual valve on the main gas

line. Have the fireplace checked by a qualified service technician.

C. Operating Remote Control

TO turn the fireplace on:

Open Door and slowly open valve on gas tank.

Press the ON button on remote control for 2 or 3 seconds to activate. The Status indicator light on control wilt illuminate green and the control box on the fireplace will sound one beep. Refer to Fig. 1.

TO turn the fireplace off:

Press the OFF button on the remote control for 2 or 3 seconds to activate. The control box on the fireplace will sound two beeps. Refer to Fig. l u

Close valve on gas tank and close Door.

To adjust the burning level:

Press UP or DW button on the remote control. The control box on the fireplace will sound two beeps. Refer to Fig. 1.

When controlling your fireplace by remote control, press button on the remote control for 1 or 2 seconds to send

signal to fireplace.

Fig. 1

 

ON button

- Signal indicator

DOWN button _

OFF button

 

UP button

To replace the battery,

Remove the screw on the back of the remote control. Remove the front cover and replace the battery with an Alkaline type MS21iMN21 size 23Ai12V. Refer to Fig. 2.

Fig. 2.

PCB_iiiiii'ii_ii_iiiiiii!iii!iiiiiiiiiiiiiiii!iiiii!iiiiiii"Signal indicatoriii!ii_i

Terminal

Battery

The fireplace requires very little maintenance. To clean simply wipe the outer case with a damp cloth. Do not use solvents or any other caustic cleaning agents because they may discolor or distort any plastic parts. Do not use aerosol polish or any other flammable material to clean the heater while it is in operation.

Trouble Shooting

m

 

Remedy

 

 

\

 

 

 

\

 

 

 

\

\

 

 

 

 

 

 

\

 

 

Strongwind

X

Retry Ignition

Dead Battery

X

Replace

Batteries

Airin gas line

 

Purge air

Gas odor

x

X Service

call

Non-ignition

Service

call

No gas flow

X

Tank empty, Manua

 

 

gas valve closed,

 

 

Service

call

I l'i'to

The fireplace is controlled by a micro processor which has the ability to check its own operation continuously. If a fault occurs an error message will appear on the status indicator on the control panel and the micro processor will automatically shut off the heater.

If an error message is displayed please refer to the list below for the possible cause of the error message and the Trouble Shooting Section on this page for a solution. You may be able to fix the problem without a service call. If the error message persists turn off the gas at the manual shutoff and contact a qualified service technician for service.

Ignition Failure:

The status indicator light will flash red for 15 seconds with single consecutive flashes. Check gas flow and all gas connections. If the problem continues call a qualified service technician.

Flame Failure:

The status indicator light will flash red for 15 seconds with two consecutive flashes. Check gas supply, LP tank. If the problem continues call a qualified service technician.

Over Heating:

The status indicator light will flash red for 15 seconds with three consecutive flashes. Check for obstruction of

air flow around fireplace casing. If the problem continues call a qualified service technician.

Gas valve Failure:

The status indicator light will flash red for 15 seconds with four consecutive flashes. Check connections of gas

valve. If the problem continues call a qualified service technician.

12

Page 12
Image 12
Grand Hall 89795 owner manual Operating Remote Control, Trouble Shooting