B. Turning the fireplace off
Press ON/OFF button to turn fireplace off.
Close valve on gas tank and close Door.
Note: If the fireplace does not turn offby pressing the
ON/OFF button, closethe manual valve on the main gas
line. Have thefireplace checked by aqualified service
technician.
C. Operating Remote Control
TOturn the fireplace on:
Open Door and slowly open valve ongas tank.
Press the ON button on remote control for 2 or 3
seconds toactivate. The Status indicator light oncontrol
wilt illuminate green and the control box on the fireplace
will sound one beep. Refer to Fig. 1.
TOturn the fireplace off:
Press the OFF button on the remote control for 2or 3
seconds to activate. The control box on the fireplace will
sound two beeps. Refer to Fig. l u
Close valve on gastank and close Door.
I l'i'to
To adjust the burning level:
Press UP or DW button on the remote control. The
control box on the fireplace will sound two beeps. Refer
to Fig. 1.
When controlling your fireplace byremote control, press
button on the remote control for 1 or 2 seconds to send
signal tofireplace.
Fig. 1
ON button -Signal indicator
DOWN button _ OFF button
UP button
To replace the battery,
Remove the screw on the back of the remote control.
Remove the front cover and replace the battery with an
Alkaline type MS21iMN21 size 23Ai12V. Refer to Fig. 2.
Fig. 2.
PCB_
Terminal
Battery
iiiiii'ii_ii_iiiiiii!iii!iiiiiiiiiiiiiiii!iiiii!iiiiiii_iii!ii_i"_ Signal indicator
Trouble Shooting
m
\\\\\
Strongwind X
DeadBattery X
Airingas line
Gasodor
Non-ignition x
Nogas flow X
Remedy
Retry Ignition
Replace Batteries
Purge air
XService call
Service call
Tankempty, Manua
gas valve closed,
Service call
The fireplace is controlled by a micro processor which
has the ability to check its own operation continuously. If
afault occurs an error message will appear on the status
indicator on the control panel and the micro processor
will automatically shut off the heater.
If an error message is displayed please refer to the list
below for the possible cause of the error message and
theTrouble Shooting Section onthis page for asolution.
You may be able tofix the problem without a service call.
If the error message persists turn off the gas at the
manual shutoff and contact a qualified service
technician for service.
Ignition Failure:
The status indicator light will flash red for 15 seconds
with single consecutive flashes. Check gas flow and all
gas connections. If the problem continues call a
qualified service technician.
Flame Failure:
The status indicator light will flash red for 15 seconds
with two consecutive flashes. Check gas supply, LP tank.
If the problem continues call a qualified service
technician.
Over Heating:
The status indicator light will flash red for 15 seconds
with three consecutive flashes. Check for obstruction of
air flow around fireplace casing. If the problem
continues call a qualified service technician.
Gas valve Failure:
The status indicator light will flash red for 15 seconds
with four consecutive flashes. Check connections of gas
valve. If the problem continues call a qualified service
technician.
The fireplace requires very little maintenance. To clean
simply wipe the outer case with a damp cloth. Donot use
solvents or any other caustic cleaning agents because
they may discolor or distort any plastic parts. Do not use
aerosol polish or any other flammable material to clean
the heater while it is in operation.
12