Table 13: Device Configuration - Status

Hardware Revision

MAC Address

IP Address

Product Model

Part Number

Software Version

System Up Time

Registered

PPPoE Link Up

Hardware version number: Main Board, Interface Board

The device ID, in HEXADECIMAL format.

This field shows IP address of GXP

This field contains the product model information.

This field contains the product part number

Program: This is the main software (firmware) release number, always used to identify the software (firmware) system of the phone.

Boot: Booting code version number

This field shows system up time since the last reboot.

Indicates whether accounts are registered to the related SIP server(s). GXP can support four unique SIP profiles.

Indicates whether the PPPoE connection is enabled (connected to a modem).

Table 14: Device Configuration – Basic Settings

 

 

 

 

 

End User

 

This contains the password to access the Web Configuration Menu. This field is

 

Password

 

case sensitive with a maximum length of 25 characters.

 

 

 

 

 

 

 

There GXP operates in two modes:

 

IP Address

 

 

 

 

 

 

1. DHCP mode: all the field values for the Static IP mode are not used (even

 

 

 

though they are still saved in the Flash memory.) The GXP acquires its IP

 

 

 

address from the first DHCP server it discovers on its LAN. The DHCP

 

 

 

option is reserved for NAT router mode. To use the PPPoE feature, set the

 

 

 

PPPoE account settings. The GXP establishes a PPPoE session if any of

 

 

 

the PPPoE fields are set.

 

 

 

2. Static IP mode: configure all of the following fields: IP address, Subnet

 

 

 

Mask, Default Router IP address, DNS Server 1 (primary), DNS Server 2

 

 

 

(secondary). These fields are set to zero by default.

 

 

 

 

 

 

 

These options are used to assign a function to the corresponding multi purpose key.

 

Multi Purpose Key X

 

 

 

 

Options available are: “Speed Dial”, “BLF”, “Presence Watcher” and “Eventlist BLF”.

 

 

 

Each function is connected to one of the accounts and has a target user ID.

 

 

 

 

 

 

 

This parameter controls the date/time display according to the specified time zone.

 

Time Zone

 

 

 

 

 

 

 

 

Turn on LC backlight at all times. Default is No. This option applies to GXP-

 

LCD Backlight Always

 

 

On

 

1200/GXP-2000 only.

 

 

 

 

 

 

 

LCD time display in 12 hour or 24 hour format

 

Time Display Format

 

 

 

 

 