Lock keypad update:

 

 

No

 

Yes (configuration update via keypad is disabled if set to

 

Yes)

 

 

 

 

 

 

Allow conf SIP Account in Basic Settings:

Override MTU Size:

No Yes

0

Update

All Rights Reserved Grandstream Networks, Inc. 2005

Admin Password

SIP Server

Outbound Proxy

SIP User ID

Authenticate ID

Authenticate

Password

Name

Preferred Vocoder

G723 Rate:

iLBC frame size

Administrator password. Only administrator can configure the “Advanced Settings” page. Password field is purposely left blank for security reason after clicking update and saved. The maximum password length is 25 characters.

This field contains the URI string or the IP address. e.g. sip.my-voip- provider.com; 192.168.1.200:5066

This field contains the URI string or the IP of the outbound proxy. If there is no outbound proxy, this field SHOULD be left blank. If it is not blank, all outgoing requests will be sent to this outbound proxy.

This field contains the user part of the SIP address for this phone. e.g., if the SIP address is: sip:my_user_id@my_provider.com, then the SIP User ID is: my_user_id. Please do NOT include the preceding “sip:” scheme or the host portion of the SIP address in this field. It is given by VoIP service provider.

SIP service subscriber’s Authenticate ID used for authentication. It can be identical to or different from SIP User ID and given by VoIP service provider.

SIP service subscriber’s account password. It is given by VoIP service provider.

SIP service subscriber’s name which will be used for Caller ID display.

HandyTone-286 supports up to 7 different vocoder types including G711-ulaw (PCMU), G711-alaw (PCMA), G723, G729A, G726-32, and iLBC. Depending on the product model, some of these vocoders may not be provided in standard release.

A user can configure vocoders in a preference order that will be offered in SIP INVITE message.

This defines the encoding rate for G723 vocoder. By default, 6.3kbps rate is chosen.

This defines the size of the iLBC codec frame. The default setting is 20ms.