Grandstream Networks HT496 user manual

Models: HT496

1 29
Download 29 pages 56.18 Kb
Page 19
Image 19
Manual background

 

Daylight Savings Time

 

Controls whether displayed time is daylight savings time or not. If set to “Yes” and the

 

 

 

 

Optional Rule is empty, then the displayed time will be 1 hour ahead of normal time.

 

 

 

 

• The “Automatic Daylight Saving Time Rule” has the following syntax:

 

 

 

 

o start-time;end-time;saving. Both start-time and end-time have the

 

 

 

 

 

same syntax: month,day,weekday,hour,minute

 

 

 

 

o month: 1,2,3,..,12 (for Jan, Feb, .., Dec)

 

 

 

 

o

day: [+-]1,2,3,..,31

 

 

 

 

o weekday: 1, 2, 3, .., 7 (for Mon, Tue, .., Sun), or 0 indicating daylight

 

 

 

 

o

savings rule is based on the day of the month.

 

 

 

 

hour: hour (0-23),

 

 

 

 

o

minute: minute (0-59)

 

 

 

 

• If “weekday” is 0, it means the date to start or end daylight savings is the given

 

 

 

 

date. The “day” value must not be negative.

 

 

 

 

• If “weekday” is not zero and “day” is positive, then daylight saving starts on the

 

 

 

 

first “day” of the week (1st Sunday, 3rd Tuesday etc).

 

 

 

 

• If “weekday” is not zero and “day” is negative, then daylight savings starts on the

 

 

 

 

last “day” of the week (last Sunday, 3rd last Tuesday etc).

 

 

 

 

• Daylight savings is in minutes. If preceded by a (-), then subtract the number of

 

 

 

 

minutes.

 

 

 

 

 

The default value for “Automatic Daylight Saving Time Rule” is US time:

 

 

 

 

“04,01,7,02,00;10,-1,7,02,00;60”.

 

 

 

 

Example: US/Canada, where daylight savings is applicable:

 

 

 

 

04,01,7,02,00;10,-1,7,02,00;60

 

 

 

 

Daylight savings starts from the first Sunday of April at 2AM and ends the last Sunday of

 

 

 

 

October at 2AM.).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device Mode

 

Enables use of the device as a router or a bridge.

 

 

 

 

 

 

 

 

 

 

 

 

 

WAN side HTTP/Telnet

 

If set to “Yes”, user can access the configuration page through the WAN port, instead of

 

 

Access

 

through the “PC” port. Warning: this configuration is less secure than default option.

 

 

 

 

Default is No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reply to ICMP on WAN

 

If set to “Yes”, the HT496 will respond to the PING command from other computers, but it

 

 

port

 

also is vulnerable to the DOS attack. Default is No.

 

 

 

 

 

 

 

 

 

 

 

 

 

Cloned WAN MAC

 

Set a specific MAC address. Set in Hex format.

 

 

Address:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAN Subnet Mask

 

Sets the LAN subnet mask. Default value is 255.255.255.0.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAN DHCP Base IP:

 

Base IP for the LAN port which functions as a gateway for the subnet. Default value is

 

 

 

 

192.168.2.1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DHCP IP Lease Time:

 

Value is set in number of hours. Default value is 120hr (5 Days.) The amount of time IP

 

 

 

 

address are assigned to LAN clients.

 

 

 

 

 

 

 

 

 

 

 

 

 

DMZ IP:

 

Forward all WAN IP traffic to a specific IP address if no matching port is used by HT496or

 

 

 

 

defined in port forwarding.

 

 

 

 

 

 

 

 

 

 

 

 

 

Port Forwarding:

 

Forwards a matching (TCP/UDP) port to a specific LAN IP address with a specific

 

 

 

 

(TCP/UDP) port.

 

 

 

 

 

 

 

 

In addition to the Basic Settings configuration page, end users also have access to the Device Status page.

Grandstream Networks, Inc.

HT496 User Manual

Page 19 of 29

 

Firmware 1.0.3.86

Last Updated: 7/2007

Page 19
Image 19