Greenheck Fan 464696 manual Coil Dimensions - continued

Models: 464696

1 16
Download 16 pages 22.49 Kb
Page 6
Image 6
Coil Dimensions - continued

Coil Dimensions - continued

Chilled Water • 4, 6 or 8 Row

 

F

 

 

 

3 in.

 

 

 

 

 

 

 

Outlet

 

 

 

 

Cap

 

 

Airflow

 

 

 

 

Outlet

 

 

 

 

 

 

E

 

 

 

 

 

Cap

Inlet

 

Inlet

 

 

2 in.

 

 

 

 

 

 

 

 

 

 

0.75 in.

3.75 in.

A

 

 

1.5 in.

1 in.

 

B

C

 

 

Drain

 

 

D

 

 

 

 

 

Connection

0.25 vent and drain supplied. Right side connection shown.

NOTE

With airflow from left to right, the fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). The other two coil connections should be capped off (Cap).

Unit

 

A

 

 

B

 

C

D

E

F

Size

4 Row

6 Row

8 Row

4 Row

6 Row

8 Row

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

3.38

3.29

3.21

6.63

8.71

10.79

20.00

22.50

22.63

0.875

 

 

 

 

 

 

 

 

 

 

 

800

3.38

3.29

3.21

6.63

8.71

10.79

20.00

22.50

22.63

0.875

1300

3.38

3.29

3.21

6.63

8.71

10.79

24.00

27.50

22.63

0.875

1600

3.38

3.29

3.21

6.63

8.71

10.79

24.75

27.25

22.63

0.875

2000

3.38

3.29

3.21

6.63

8.71

10.79

24.75

27.50

25.13

0.875

 

 

 

 

 

 

 

 

 

 

 

2400

3.38

3.29

3.21

6.63

8.71

10.79

24.75

27.50

25.13

0.875

 

 

 

 

 

 

 

 

 

 

 

3000

3.38

3.29

3.21

6.63

8.71

10.79

28.75

31.25

22.63

1.375

 

 

 

 

 

 

 

 

 

 

 

All dimensions are in inches.

Direct Expansion (DX) Single Circuit • 4, 6 or 8 Row (Orifice Code 18/19)

1.625 in.

1.125 in.

 

3 in.

 

 

 

Cap

 

Cap

 

 

 

Airflow

Inlet

 

Inlet

 

 

 

E

Outlet

2 in.

Outlet

 

 

 

 

 

 

 

1.5 in.

0.75 in.

 

 

 

3.75 in.

A

 

1 in.

B

 

 

C

 

Drain

 

D

 

Connection

Right side connection shown.

NOTE

With airflow from left to right, the fluid enters the coil from the center connection (Inlet) and exits from the bottom (Outlet). The other coil connections should be capped off (Cap).

Unit

 

A

 

 

B

 

C

D

E

Size

4 Row

6 Row

8 Row

4 Row

6 Row

8 Row

 

 

 

 

 

 

 

 

 

 

 

 

 

600

3.38

3.29

3.21

5.66

6.25

7.33

20.00

22.50

13.19

800

3.38

3.29

3.21

5.66

6.25

7.33

20.00

22.50

13.19

1300

3.38

3.29

3.21

5.66

6.25

7.33

24.00

27.50

13.19

1600

3.38

3.29

3.21

5.66

6.25

7.33

24.75

27.25

13.19

 

 

 

 

 

 

 

 

 

 

2000

3.38

3.29

3.21

5.66

6.25

7.33

24.75

27.50

14.44

 

 

 

 

 

 

 

 

 

 

2400

3.38

3.29

3.21

5.66

6.25

7.33

24.75

27.50

14.44

 

 

 

 

 

 

 

 

 

 

3000

3.38

3.29

3.21

5.66

6.25

7.33

28.75

31.25

13.19

All dimensions are in inches.

6 Model VFCD/VFCB Vertical Fan Coil

®

Page 6
Image 6
Greenheck Fan 464696 manual Coil Dimensions - continued