Greenheck Fan QEI-L, QEID manual Certifications & Listings

Models: QEI-L QEID QEI

1 52
Download 52 pages 47.13 Kb
Page 10
Image 10
UL/cUL File E40001
UL/cUL Listed Power Ventilator

Certifications & Listings

Seismic Certification

The International Building Code (IBC) has been adopted at the state and level throughout the United States. With the adoption of this code, comes introduction of standards intended to improve the performance and design non-structural systems subject to seismic events.

QEI-I/II and QEID

Meet the 2006 IBC, 2009 IBC

California OSHPD requirements (horizontal mount only) OSP 0223-10

Shake table tested at an independent test facility in accordance with ICC-ES AC 156

All equipment certified to worst case scenario seismic conditions

-

Importance factor of 1.5 (IP = 1.5)

-

Occupancy Categories (I - IV)

-

Site Classes (A - F)

-

Seismic Design Categories (A - F)

Structural Finite Element Analysis

Seismic Design Category F

Consult your Greenheck representative or visit greenheck.com/seismic for more details.

UL 705 Power Ventilator

QEI-L, QEI-I/II and QEID models are available with the UL/cUL 705 (Underwriters Laboratory) listing on a wide variety of 50 and 60 Hz motors. This listing ensures the use of UL approved electrical components.

Motors are available as either IEC (IP55) or NEMA (TEAO or ODP) designs. IEC design motors are adjustable speed drive (ASD) compatible, have class F insulation and are capable of wye-delta starting when over 5.5 kW. NEMA motors use across the line starting with options for ASD compatibility. Motor (IEC or NEMA) using 50 Hz power have

a 1.0 service factor, while 60 Hz power have 1.15 service factor. Design and construction options for motors include increased thermal insulation, overload protection and extended motor leads.

UL Emergency Smoke Evacuation

QEI-I/II and QEID models were tested and rated for design time and temperature used in emergency heat and smoke exhaust applications.

UL/cUL File MH17511

UL/cUL Power Ventilators for Smoke Control Systems

 

Operating

Time

 

Model

Temperature

Duration

 

 

ºC

ºF

Hours

Comments

 

 

 

 

 

QEID

300

572

1

Per British Spec 7346

 

 

 

 

QEI-I/II

300

572

2

 

 

 

 

 

 

QEI-I/II

260

500

4

Per Industrial Risk

QEID

260

500

5

Insurers (North America)

 

 

 

 

 

Consult your Greenheck representative for time and temperature combinations other than those listed.

UL 762 Restaurant Exhaust

Inline grease exhaust fans are an excellent alternative for kitchen applications when roof or wall mounted ventilators are not practical. A QEI-I/II with UL 762 grease option is designed to withstand the demands of high temperature kitchen grease exhaust and high-pressure duct washers.

A Tough Package to Beat

The QEI-I/II inline grease fan is tough to beat when packaged with our full line of kitchen hoods and grease extraction options. Take advantage of Greenheck’s expertise in providing a total solution in kitchen ventilation equipment.

10

Listed Power Ventilation for Restaurant Exhaust Appliances 13G3 Maximum Operating Temperature 400°F.

UL 762 is concerned with fans designed for removal of smoke and grease laden vapors with airstream temperatures up

to 400°F.

Meets all UL 705 requirements

UL/cUL File MH11745 UL/cUL Power Ventilators for Restaurant Exhaust Appliances

Bolted access door

Drain connection

Meets requirements of NFPA 96 Ventilation Control and Fire Protection of Commercial Cooking Operations

Page 10