Greenheck Fan QEID, QEI-L manual QEI-15 Class, 100 kg

Models: QEI-L QEID QEI

1 52
Download 52 pages 47.13 Kb
Page 23
Image 23

QEI-15 Class II

Performance Data

Maximum Fan RPM

3445

 

 

 

Specification Data

 

 

 

 

 

Maximum Motor

215T

Frame Size

 

 

 

 

 

Minimum Motor

1/3 hp

.25 kW

Starting hp

 

 

 

 

 

Wheel Diameter

18.25 in.

464 mm

 

 

 

Approximate Weight

220 lbs.

100 kg.

(Less Motor & Drives)

 

 

 

 

 

Maximum Bhp = (Fan RPM / 1666)3

 

Outlet Velocity (FPM) = CFM / 2.32

Tip Speed (FPM) = Fan RPM x 4.78

% WOV = (CFM x 100) / (Fan RPM x 2.20)

Static Pressure (Pa x 100)

20

15

10

5

0

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50% WOV

 

 

RPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60% WOV

BHP

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% WOV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Density

0.075 lb/ft3

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Density 1.2 kg/m3

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

70% WOV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

wg)

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

80% WOV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

C

 

 

 

 

(in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

6

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

3445

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

S

 

 

3259

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

T

H

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2847

 

 

 

 

Static

 

 

 

 

 

 

 

 

 

 

 

 

F

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

90% WOV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2402

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

T

T

 

 

 

 

 

 

 

 

 

 

 

 

 

2099

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1666

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

1

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

3

4

5

6

7

8

Imperial data — Metric data

Performance Data

Volume (cfm x 1000)

0

2

4

6

8

10

12

Volume (m3/hr x 1000)

 

 

 

 

 

 

 

 

 

 

 

STATIC PRESSURE (inches wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

OV

0.5

 

1

 

 

2

3

 

4

 

5

 

6

 

7

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RPM

 

BHP

RPM

 

BHP

RPM

 

BHP

RPM

 

BHP

RPM

 

BHP

RPM

 

BHP

RPM

 

BHP

RPM

 

BHP

RPM

 

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2500

1077

1315

 

0.42

1471

 

0.64

1790

 

1.23

2082

 

1.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2800

1206

1436

 

0.53

1575

 

0.77

1864

 

1.38

2131

 

2.09

2392

 

2.88

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3100

1336

1559

 

0.65

1687

 

0.92

1948

 

1.54

2201

 

2.29

2435

 

3.11

2670

 

3.99

2884

 

4.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3400

1465

1684

 

0.79

1805

 

1.10

2034

 

1.72

2275

 

2.51

2500

 

3.36

2713

 

4.28

2926

 

5.25

3122

 

6.28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3700

1594

1810

 

0.96

1926

 

1.30

2137

 

1.95

2358

 

2.75

2570

 

3.64

2771

 

4.59

2968

 

5.59

3164

 

6.66

3347

 

7.76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4000

1724

1938

 

1.15

2047

 

1.52

2242

 

2.21

2443

 

3.01

2647

 

3.94

2841

 

4.92

3023

 

5.96

3207

 

7.05

3389

 

8.20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4300

1853

2067

 

1.37

2170

 

1.76

2353

 

2.50

2538

 

3.31

2730

 

4.26

2913

 

5.29

3093

 

6.36

3261

 

7.48

3431

 

8.65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4600

1982

2197

 

1.61

2294

 

2.04

2471

 

2.84

2641

 

3.67

2816

 

4.61

2995

 

5.67

3164

 

6.78

3331

 

7.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4900

2112

2328

 

1.89

2420

 

2.34

2590

 

3.22

2746

 

4.05

2908

 

5.01

3080

 

6.09

3243

 

7.24

3402

 

8.43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5200

2241

2460

 

2.20

2546

 

2.67

2710

 

3.64

2856

 

4.49

3011

 

5.47

3165

 

6.53

3326

 

7.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5500

2370

2592

 

2.55

2673

 

3.04

2831

 

4.07

2973

 

4.99

3115

 

5.96

3259

 

7.04

3411

 

8.23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5800

2500

2724

 

2.93

2802

 

3.45

2953

 

4.53

3092

 

5.53

3221

 

6.50

3362

 

7.61

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shaded values show where Class I fan selections are more efficient than Class II.

 

Inlet Sound Power, LWi

[dB ref 10-12watts]

 

 

RPM

% WOV

1

2

3

 

4

5

6

7

8

LWiA

 

100

64

70

70

 

72

66

65

55

48

73

1000

80

62

66

67

 

66

63

60

52

43

68

60

61

62

63

 

62

61

58

51

42

65

 

 

 

50

62

63

63

 

62

60

58

51

41

65

 

100

67

69

73

 

74

71

72

64

56

78

1400

80

66

65

71

 

72

68

67

61

53

75

60

67

66

68

 

68

66

65

58

51

71

 

 

 

50

69

67

69

 

67

65

63

57

52

71

 

100

71

73

78

 

77

77

75

79

66

84

2000

80

67

69

76

 

75

74

73

70

62

79

60

71

71

74

 

74

72

71

68

61

77

 

 

 

50

75

74

76

 

74

72

71

67

61

77

 

100

78

78

79

 

85

85

83

87

77

91

2700

80

79

74

76

 

85

84

80

77

71

88

60

81

78

77

 

82

82

78

75

70

85

 

 

 

50

81

80

79

 

82

81

78

74

70

85

 

100

79

82

84

 

89

90

88

91

87

96

3445

80

75

79

81

 

85

87

85

83

78

91

60

79

83

82

 

82

84

83

81

77

89

 

 

 

50

81

85

85

 

86

85

82

80

77

90

Outlet Sound Power, LWo [dB ref 10-12watts]

RPM

% WOV

1

2

3

4

5

6

7

8

LWoA

 

100

76

75

69

72

70

67

55

47

74

1000

80

75

72

67

67

68

62

53

44

71

60

75

72

67

64

66

60

53

44

69

 

 

50

75

71

67

64

65

60

52

44

68

 

100

80

76

74

76

76

73

66

56

80

1400

80

78

74

71

72

74

69

62

52

77

60

79

75

71

70

72

67

60

52

75

 

 

50

79

75

71

70

72

67

60

52

75

 

100

90

81

81

83

82

78

79

66

87

2000

80

88

78

77

79

80

76

72

65

84

60

87

82

78

77

78

74

69

63

82

 

 

50

89

83

79

78

78

73

69

64

82

 

100

87

85

85

88

90

86

86

78

94

2700

80

85

85

83

83

88

83

79

72

90

60

88

89

87

82

86

81

77

71

89

 

 

50

89

90

87

83

86

80

77

72

89

 

100

91

90

91

93

95

93

92

89

100

3445

80

89

92

91

89

92

89

86

80

96

60

92

94

93

87

90

87

84

79

94

 

 

50

93

94

93

89

90

87

83

78

94

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

The sound power level ratings shown are in decibels, referred to 10-12watts, calculated per AMCA Standard 301. Values shown are for inlet LWi , LWi A and outlet LWo , LWo A sound power levels for installation type B: Free inlet, Ducted outlet. Ratings for inlet sound do not include the effects of duct end correction. Ratings for outlet sound include the effects of duct end correction. The A-weighted sound power ratings shown have been calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to LWi A and LWo A values only.

23

Page 23
Image 23
Greenheck Fan QEID, QEI-L manual QEI-15 Class, 100 kg