SQ 80-85 - Direct Drive
1
(25)
117⁄8
(302)
15 | 16 | |
(381) | ||
(406) | ||
|
Damper size = 12 x 12 (305 x 305) Unit weight** = 41 (19)
Housing thickness = 18 ga Outlet velocity = 1.021 x cfm
15
(381) (Pa) PressureStatic
180
160
140
120
100
80
60
40
20
0
| 0.8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RPM (Direct) |
|
| 0.7 |
|
|
|
|
|
|
|
|
|
|
|
|
| RPM (Vari Green) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Density 0.075 lb/ft 3 |
| |
|
|
|
|
|
|
|
| E |
|
| 085- |
| Density 1.2 kg/m 3 |
| ||
|
|
|
|
|
|
|
| V |
|
|
|
|
| |||
|
|
|
|
|
|
|
| R | 080 |
| VG |
|
|
| ||
| 0.6 |
|
|
|
|
|
| U |
|
|
|
| ||||
|
|
|
|
|
|
|
| C |
|
| - |
|
|
|
| |
wg) |
|
|
|
|
|
|
| M |
|
| VG |
|
|
|
| |
|
|
|
|
|
|
| E | 085 |
|
|
|
|
| |||
|
|
|
|
|
|
| T |
|
|
|
|
| ||||
|
|
|
|
|
|
| S |
|
|
|
|
| ||||
| 0.5 |
|
|
|
|
|
| Y |
|
| - |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| D |
|
|
|
| ||
(in. |
|
|
|
|
|
|
| S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| S | 080 |
|
|
|
|
| |||
|
|
|
|
|
|
| I |
|
|
|
|
| ||||
|
|
|
|
|
|
|
| H |
|
|
|
|
| |||
Pressure |
|
|
|
|
|
|
| T |
|
| D |
|
|
|
| |
0.4 |
|
|
|
|
|
| F |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| O |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| T |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| F | 085 |
|
|
|
|
|
| ||
|
|
|
|
|
|
| E |
|
|
|
|
|
| |||
|
|
|
|
|
|
| L |
|
|
|
|
|
| |||
|
|
|
|
|
|
| E |
| - |
|
|
|
|
| ||
0.3 |
|
|
|
|
|
|
|
| G |
|
|
|
| |||
|
|
|
|
|
|
| H | 080 |
|
|
|
|
|
| ||
Static |
|
|
|
|
|
|
| T |
|
|
|
|
|
| ||
|
|
|
|
|
|
| O |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| - |
|
|
|
|
| |||
|
|
|
|
|
|
|
| G |
|
|
|
| ||||
|
|
|
|
|
|
| T |
|
|
|
|
| ||||
|
|
|
|
|
|
| T |
|
|
|
|
|
|
|
| |
0.2 |
|
|
|
|
|
| C |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| E | 085 |
|
|
|
|
|
| ||
|
|
|
|
|
|
| L |
|
|
|
|
|
| |||
|
|
|
|
|
| E |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| - |
|
|
|
|
| |||
|
|
|
| O | T | S |
|
| 080 |
| E |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| 0.1 |
| N |
|
|
|
|
|
| E |
|
|
|
|
| |
|
| D | O |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0.00 |
|
|
|
|
|
| 100 | 200 |
|
|
| 300 | 400 | 500 | 600 |
|
|
|
|
|
|
|
|
|
| Volume (cfm) |
|
|
|
Dimensions shown in inches (millimeters) and weight is |
|
|
|
|
|
|
|
0 | 200 | 400 | 600 | 800 | 1000 | ||
shown in pounds (kilograms). |
|
| Volume (m 3/hr) |
|
|
| |
**Weight shown is largest cataloged Open Drip Proof motor. |
|
|
|
|
|
Motor HP
Direct
Fan RPM
CFM / Static Pressure in Inches wg
0.000 | 0.100 | 0.125 | 0.200 | 0.250 | 0.300 | 0.375 | 0.400 | 0.450 | 0.500 |
|
|
|
|
|
|
|
|
|
|
80
or 1/4
|
| CFM | 306 | 241 | 225 | 167 | 105 |
|
|
|
|
|
1050 | BHP | 0.01 | 0.01 | 0.02 | 0.02 | 0.02 |
|
|
|
|
| |
|
| Sones | 3.8 | 3.7 | 3.6 | 3.8 | 4.1 |
|
|
|
|
|
|
| CFM | 379 | 325 | 313 | 274 | 244 | 211 | 140 |
|
|
|
1300 | BHP | 0.02 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 |
|
|
| |
|
| Sones | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.5 |
|
|
|
|
| CFM | 452 | 405 | 395 | 364 | 343 | 319 | 280 | 266 | 238 | 201 |
1550 | BHP | 0.04 | 0.04 | 0.04 | 0.05 | 0.05 | 0.05 | 0.06 | 0.06 | 0.06 | 0.06 | |
|
| Sones | 7.3 | 7.3 | 7.3 | 7.3 | 7.2 | 7.3 | 7.3 | 7.4 | 7.5 | 7.6 |
|
| CFM | 503 | 461 | 451 | 423 | 404 | 385 | 354 | 342 | 319 | 294 |
| 1725 | BHP | 0.05 | 0.05 | 0.05 | 0.06 | 0.06 | 0.07 | 0.07 | 0.07 | 0.08 | 0.08 |
|
| Sones | 8.4 | 8.5 | 8.6 | 8.5 | 8.6 | 8.6 | 8.6 | 8.6 | 8.7 | 8.7 |
85
or 1/4
|
| CFM | 358 | 292 | 272 | 206 | 142 |
|
|
|
|
|
1050 | BHP | 0.01 | 0.02 | 0.02 | 0.02 | 0.02 |
|
|
|
|
| |
|
| Sones | 3.8 | 3.7 | 3.6 | 3.8 | 4.0 |
|
|
|
|
|
|
| CFM | 443 | 391 | 378 | 332 | 299 | 261 | 186 |
|
|
|
1300 | BHP | 0.02 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 |
|
|
| |
|
| Sones | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.5 |
|
|
|
|
| CFM | 528 | 485 | 474 | 440 | 414 | 387 | 344 | 328 | 294 | 254 |
1550 | BHP | 0.04 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.06 | 0.06 | 0.06 | 0.06 | |
|
| Sones | 7.3 | 7.3 | 7.3 | 7.3 | 7.3 | 7.2 | 7.3 | 7.3 | 7.4 | 7.5 |
|
| CFM | 588 | 550 | 540 | 510 | 488 | 465 | 429 | 416 | 391 | 362 |
| 1725 | BHP | 0.06 | 0.06 | 0.06 | 0.07 | 0.07 | 0.07 | 0.08 | 0.08 | 0.08 | 0.08 |
|
| Sones | 8.7 | 8.7 | 8.6 | 8.6 | 8.6 | 8.6 | 8.7 | 8.7 | 8.7 | 8.8 |
Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).
The sound ratings shown are loudness values in fan sones at 1.5 m (5 feet) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are for installation type B: free inlet hemispherical sone levels.
17