Step 5: Re-adjust Input Levels, if necessary - “fine-tune” input black

Section 3: Operation

4c) Adjust color temperature to match whites between screens (keep White Boost at 0) – View all white fields and adjust Red, Green, Blue in the Color Temperature window.

When matching light output of individual projectors it may be necessary to adjust the White Boost level. Start with White Boost at 0 and match to the dimmest display.

 

 

 

Figure 3.38.

 

 

 

Step 5: Re-adjust Input Levels, if necessary - “fine-tune” input black

 

 

 

levels to match grey scale color. Refer to Black Levels and Input Drives on page

 

 

 

3-16 for instructions.

 

 

 

All color screens should now be color matched. For each projector, the settings

 

 

 

define your chosen User color temperature. For best results, keep all projectors at

 

 

 

the same lamp power – the light output from each will be maintained over time to

 

 

 

within 10% of the current level.

 

 

 

Occasionally the projector encounters error conditions, which interrupt normal

 

3.8 Error Codes

 

 

 

operation. These can be caused by invalid user entry, an input signal error (most

 

 

 

 

 

 

common) or some other system error. You will automatically be notified of such

 

 

 

errors on-screen and via serial communications.

 

Invalid User Errors

' Invalid user entry errors trigger an on-screen message to appear (usually in the

 

 

 

bottom right corner of the screen) describing the problem. Press Exit to confirm

 

 

 

the message and close the message box.

 

Input Signal Errors

' Input signal error messages appear when you are in presentation level (ie. When

 

 

 

there are no menus present) and have selected an input on which the projector

 

 

 

detects a problem. While menus remain operational and pressing any key will

 

 

 

temporarily remove the message from the screen, you must resolve the signal

 

 

 

problem in order to permanently eliminate the message.

System Warnings/Errors

' A system warning message indicates that a system malfunction has been detected

 

 

 

(see Status LED Codes, below). It replaces any input signal message and

 

 

 

disappears when the input signal status changes. While the projector will remain

 

 

 

operational, the message indicates the presence of a serious problem that should

 

 

 

be reported to the manufacturer. You can press Exit to remove the message, but

 

 

 

for best results you should reset the projector—power the projector down and up

 

 

 

again with the Power key.

 

 

 

Status LED Codes

 

 

 

There are three LEDs on the EM that are used to convey the current state of the

 

 

 

system and report any error conditions that may be present.

If the POWER LED on the back of the projector repeatedly flashes a pattern of yellow and red light, you have likely encountered a system error requiring the