Operation

Operation

Switch Modes

After configuring, mounting and connecting your Inverter/Charger, you are able to operate it by switching between the following operat- ing modes as appropriate to your situation:

“AUTO/REMOTE”: Switch to this mode when you need constant, uninterrupted AC power for connected appliances and equipment. The Inverter/Charger will

continue to supply AC power to connected equipment and to charge your connected batteries while utility-

or generator-supplied AC power is present. Since the

inverter is ON (but in Standby) in this mode, it will automatically switch to your battery system to supply AC power to connected equipment in the absence of a utility/generator source or in over/ under voltage situations. “AUTO/REMOTE” also enables an option- al remote control module (Tripp Lite model APSRM4, sold sepa- rately) to function when connected to the unit.

“CHARGE ONLY”: Switch to this mode when you

are not using connected appliances and equipment in order to conserve battery power by disabling the

inverter. The Inverter/Charger will continue to sup- ply AC power to connected equipment and charge connected batteries while utility- or generator-sup-

plied AC power is present. However, since the inverter is OFF in this mode, it WILL NOT supply AC power to connected equipment in the absence of a utility/generator source or in over/under voltage situations.

“DC OFF”: Switch to this mode to prevent the inverter from drawing power from the batteries. Use

this switch to automatically reset the unit if it shuts

Indicator Lights (Continued)

“INV” (Inverting) Yellow LED: This light will ILLUMINATE CONTINUOUSLY whenever con- nected equipment is receiving battery-supplied, inverted AC power (in the absence of a utility/genera- tor source or in over/under voltage situations). This light will be off when AC power is supplying the load.

“LOAD” Red LED: This red light will ILLUMINATE CONTINUOUSLY whenever the inverter is func- tioning and the power demanded by connected appli- ances and equipment exceeds 100% of load capacity. The light will BLINK to alert you when the inverter shuts down due to a severe overload or overheating.

If this happens, turn the operating mode switch to “DC OFF”; remove the overload and let the unit cool. You may then turn the operating mode switch to either “AUTO/REMOTE” or “CHARGE ONLY” after it has adequately cooled. This light will be off when AC power is supplying the load.

"BATT VOLTAGE" LEDs: If the operating mode switch is in the "AUTO/REMOTE" or "CHARGE ONLY" position, the LEDs indi- cate the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions. See Chart for charge and voltage levels.

LED Function with Switch in "AUTO/REMOTE" or “Charge Only” Position

Approximate Battery Charge Level*

down due to overload or overheating. First remove the excessive load or allow the unit to sufficiently

cool (applicable to your situation). Switch to "DC OFF", then back to "AUTO/REMOTE" or "CHARGE ONLY" as desired. If unit fails to reset, remove more load or allow unit to cool further and retry. Use an optional remote control module (Tripp Lite model APSRM4, sold separately) to reset unit due to overload and overtemperature.

CAUTION: The unit will always pass AC power through to con- nected equipment if plugged into a live AC outlet, regardless of the position of the Operating Mode Switch.

Indicator Lights

Your Inverter/Charger is equipped with a simple, intuitive, user-

 

 

LEDs

Battery Capacity

 

 

Illuminated

(Charging/Discharging)

 

 

Green

91%–Full

 

1

 

 

 

Green & Yellow

81%–90%

2

 

 

 

Yellow

61%–80%

3

 

 

 

Yellow & Red

41%–60%

4

 

 

 

Red

21%–40%

5

 

 

 

All three lights off

1%–20%

6

 

 

 

Flashing red

0% (Inverter

7

 

 

 

 

shutdown)**

1

2

4

5

7

3

6

friendly set of indicator lights. These easily-remembered “traffic light” signals will allow you, shortly after first use, to tell at a glance a wide variety of operating details.

“LINE Green LED”: If the operating mode switch is set to “AUTO/ REMOTE”, this light will ILLUMINATE Switch Modes CONTINUOUSLY when your connected equipment Indicator Lights (Continued)

is receiving continuous AC power supplied from a utility/generator source.

If the operating mode switch is set to “CHARGE ONLY”, this light will BLINK to alert you that the

unit’s inverter is OFF and will NOT supply AC power in the absence of a utility/generator source or in over/under voltage situations.

*Charge levels listed are approximate. Actual conditions vary depending on battery condition and load. ** Inverter shutdown protects battery against damage due to excessive discharge.

Fault Condition

 

 

 

 

LEDs

Fault

 

 

 

Illuminated

Condition

 

 

1

All three lights

Excessive discharge

1

2

 

flash slowly*

(Inverter shutdown)

 

All three lights

Overcharge (Charger

2

 

flash quickly**

shutdown)

*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼ second off. Charger shutdown protects battery against damage due to overcharge. May also indicate a battery charger fault exists. See Troubleshooting section.