Factory/Field Test Menu (cont.)
Step | Function | Operation | Description | |
|
|
|
| |
1 | LED Test | All LEDs ON | Verify that all LEDs turn on. | |
|
|
|
| |
2 | Firmware Version | Display firmware version | Shows the software version of the control. | |
|
|
|
| |
3 | Date Code | Not used | Not used | |
|
|
|
| |
4 | EEPROM Version | Not used | Not used | |
|
|
|
| |
5 | Non Resetable Unit | Scroll | Shows the total number of brews made by | |
| Counter |
| the brewer (both sides if a double unit) | |
|
|
|
| |
6 | Display Water | Show averaged A/D reading of temperature | Shows the current temperature in °F of the | |
| Temperature |
| thermister. | |
|
|
|
| |
7 | Display Water Level 1 | Show averaged A/D reading of water level 1 | If > 500 water level is full, | |
|
|
| If < 500 water level is not full. | |
|
|
|
| |
8 | Display Water Level 2 | Show averaged A/D reading of water level 2 | If > 500 water is at the heater level, | |
|
|
| If < 500 water level not at the heater level. | |
|
|
|
| |
9 | Show Input | Display scrolls “InPut” | Input Test Mode | |
|
|
|
| |
10 | Input Test | Press each key and the display will show a | Right Side | |
|
| number related to that key | On/Off - 1 (advances test) | |
|
|
| Up - 5 | |
|
|
| Down - 3 | |
|
|
| Large Brew - 4 | |
|
|
| Medium Brew - 2 | |
|
|
| Small Brew - 0 | |
|
|
| Basket Switch - 17 | |
|
|
| Left Side | |
|
|
| On/Off - 9 | |
|
|
| Up - 13 | |
|
|
| Down - 11 | |
|
|
| Large Brew - 12 | |
|
|
| Medium Brew - 10 | |
|
|
| Small Brew - 8 | |
|
|
| Basket Switch - 16 | |
|
|
|
| |
11 | Show Output | Display scrolls “outPut” | Output Test Mode | |
|
|
|
| |
12 | Output Test | Turns on each relay separately. Displays | Scroll through relay outputs with the UP | |
|
| “O##“ where: | and DOWN keys. | |
|
| ## = 2 digit output number | Outputs are as follows: | |
|
| IMPORTANT: Each output will be turned | O01 | - Fill Valve |
|
| ON when its number is on the display | O02 | - Right Bypass Valve |
|
| REGARDLESS of temperature or fill | O03 | - Left Bypass Valve |
|
| level. Be CAREFUL not to overfill the | O04 | - Right Brew Valve |
|
| tank and keep electric items out of the | O05 | - Left Brew Valve |
|
| way of the brew channel. | O06 | - not used |
|
|
| O07 | - Tank Heater |
|
|
| O08 | - Right Basket Lock |
|
|
| O09 | - Left Basket Lock |
|
|
| O10 | - not used |
|
|
|
|
|
Shuttle Brewers & Airpot/Shuttle Brewers | Page 19 |