Grindmaster APBIC-330V2E230 Heating Problems, Troubleshooting cont, Filling Problems, Remedy

Models: APB-430V2E230 APBIC-330V2E230 APB-430V2 APBIC-330V2 APBVSA-430V2E230 APB-330V2E230 APB-330V2 APBVSA-430V2 PBIC-430V2E230 APBIC-430V2 APBVSA-330V2 APBVSA-330V2E230

1 44
Download 44 pages 18.12 Kb
Page 22
Image 22
Heating Problems

Troubleshooting (cont.)

Filling Problems

Problem

Possible Causes

Service Check

Remedy

 

 

 

 

Tank does not refill

• Fill valve or control

• Check to ensure proper

• If 6 pin connector is securely

 

board is faulty

connection between

attached to control board and

 

 

6 pin connector and con-

all connections are secure

 

 

trol board. Check

and there is 24 Vac across

 

 

for proper connections

fill valve terminals, replace

 

 

at fill valve terminals.

fill valve.

 

 

Drain 1 gal. (3.8L) of

 

 

 

water from hot water

 

 

 

faucet. Check for 24 Vac

 

 

 

across fill valve

 

 

 

terminals.

 

 

 

 

 

Heating Problems

Problem

Possible Causes

Service Check

Remedy

 

 

 

 

Tank does not heat

• No electrical power to

• Check for proper voltage

• Establish electrical power

 

equipment

at terminal block. Check

to unit.

 

 

circuit breaker on supply

 

 

 

circuit.

 

 

• No power to control

• Check for proper voltage

• If there is not proper voltage

 

board

across transformer

across primary, proceed to step

 

 

primary terminals by

entitled “No power to control

 

 

disconnecting terminals.

board and transformer not

 

 

See wiring diagram for

powered”. If there is proper

 

 

more information.

voltage across primary, proceed

 

 

 

to step entitled “No power

 

 

 

to control board and

 

 

 

transformer powered”.

 

 

 

 

Page 22

Shuttle Brewers & Airpot/Shuttle Brewers

Page 22
Image 22
Grindmaster APBIC-330V2E230 Heating Problems, Troubleshooting cont, Filling Problems, Possible Causes, Service Check, Page