Grizzly G0511 instruction manual Circuit Requirements, Model G0506/G0507

Models: G0506 G0511 G0507

1 56
Download 56 pages 29.13 Kb
Page 8
Image 8

SECTION 3: CIRCUIT REQUIREMENTS

Model G0506/G0507

The Model G0506/G0507 Bandsaw is pre-wired for single-phase, 220V operation. Under normal use, the Model G0506 2 HP motor draws approx- imately 12 amps. We recommend a 15 amp cir- cuit. This includes a 15 amp circuit breaker, plug, receptacle and wiring rated for at least 15 amps. Under normal use, the Model G0507 3 HP motor draws approximately 22 amps. We recommend a 25 amp circuit. This includes a 25 amp circuit breaker, plug and wiring rated for at least 25 amps. These circuits should be satisfactory for normal use, while providing enough protection against damage caused by an overloaded circuit. If frequent circuit failures occur when using the bandsaw, contact our service department or your local electrical contractor.

This bandsaw must be connected to its own ded- icated circuit; it should not share a circuit with any other machine. A standard 2-pole breaker is nec- essary for use with the Model G0506/G0507.

This bandsaw is not supplied with a cord and power plug. We recommend using a NEMA-style L6-25 plug and outlet similar to Figure 1. You may also “hard-wire” the bandsaw directly to your panel, provided you place a disconnect switch near the machine. Check the electrical codes in your area for specifics on wiring requirements.

Please refer to the wiring diagram on page 30 for power hook-up information.

Figure 1. Typical 220V 3-prong plug and outlet.

Be sure that your particular electrical config- uration complies with local and state codes. The best way to ensure compliance is to check with your local municipality or a licensed electrician.

-6-

18" & 20" Super Heavy-Duty Bandsaws

Page 8
Image 8
Grizzly G0511 instruction manual Circuit Requirements, Model G0506/G0507