Grizzly G0508 owner manual Blast Gate

Models: G0508

1 44
Download 44 pages 34.79 Kb
Page 26
Image 26

Always guard against static electrical build up by grounding all dust collection lines.

Ensure that the entire system is grounded. If using plastic blast gates to direct air flow, the grounding wire must be jumped (Figure 32) around the blast gate without interruption to the grounding system.

 

Plastic

 

Blast Gate

Copper

 

Ground

Metal Duct

Wire

 

Figure 32. Ground jumper wire when using

plastic blast gates and metal duct.

External Ground

 

Wire

 

Internal

 

Ground

Ground Screw

Wire

 

Flex-Hose Figure 33. Flex-hose grounded to machine.

We also recommend wrapping the outside of all plastic ducts with bare copper wire to ground the outside of the system against static electrical build up. Wire connections at Y’s and T’s should be made with wire nuts.

Attach the bare ground wire to each stationary woodworking machine and attach to the dust collector frame with a ground screw as shown in Figure 33. Ensure that each machine is continu- ously grounded to the grounding terminal in your electric service panel.

-24-

G0508 10 HP Industrial Dust Collector

Page 26
Image 26
Grizzly G0508 owner manual Blast Gate