220V Operation

If the machine is not wired correctly a fire could result. Make sure your wiring, recep- tacle, plug, and circuit breaker can handle the current draw of the machine. If you are not sure that your electrical circuit can han- dle the current draw, get a qualified electri- cian to test your electrical system and do any required upgrades. Do not attempt to modify an existing circuit by only replacing the circuit breaker with one rated for a high- er amperage draw than the wiring, recepta- cle, and plug are rated for.

The motors supplied with the Models ZFX, PROZ, & PROZX are prewired to operate at 220V.

Models ZFX, PROZ, & PROZX:

Under normal 220V use, the motor draws approx- imately 13 amps. Use a 15 amp circuit breaker or a 15 amp slow-blow fuse for 220V operation.

The Models ZFX, PROZ, & PROZX do not come with a plug. When operating at 220V, use a NEMA-style 6-15 plug and receptacle as shown in Figure 6.

Figure 6. NEMA-style 6-15 plug and receptacle.

The circuit you use should be dedicated, (i.e., the machine should provide the only draw from that circuit). If frequent circuit failures occur when using this machine, contact our Service Department or your local electrical contractor.

 

 

 

 

 

 

 

 

 

 

 

 

-10-

 

G1022 Series Table Saws

Page 12
Image 12
Grizzly G1022SM instruction manual 220V Operation, Models ZFX, PROZ, & Prozx