Miter Gauge

The miter gauge for the Model G1023S Series has two setscrews in the miter bar which can be set to remove any loose movement between the miter bar and the T-slot.

To adjust the miter gauge:

1.Loosen or tighten the two miter bar setscrews (Figure 23) until the miter gauge slides freely in the slot, but has no loose movement.

2.Loosen the lock knob on the miter gauge and place a square against the face of the miter body and the miter bar.

3.Adjust the miter body until there is no space between the square and the miter bar.

4.Tighten the lock knob.

5.With the stop link (Figure 23) in the up posi- tion, loosen the jam nut and adjust the stop screw until it is seated against the stop link.

6.Loosen the setscrew on the left front side of the miter bar, adjust the pointer to 90û and retighten the setscrew.

7.To adjust to 45û, follow Steps 1-6while using an adjustable square.

8.After rotating the miter body from 45û to 90û and back a few times, double check your adjustments at both angles to ensure that you have accurately set your miter gauge.

Setscrew

Stop Link

Stop Screw

Jam Nut

Figure 23. Miter gauge adjustment points.