SECTION 2: CIRCUIT

REQUIREMENTS

110V Operation

Serious personal injury could occur if you connect the machine to the power source before you have com- pleted the set up process. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The motors on the air compressors will draw the following amps:

G0464 Motor Draw

...................... 8

Amps

G0465 Motor Draw

...................... 8

Amps

G0467 Motor Draw

..................14.5

Amps

G0468 Motor Draw

...................... 8

Amps

G0470 Motor Draw

14

Amps

Circuit Requirements

Only connect your machine to a cir- cuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same cir- cuit. If you are unsure, consult a qualified electrician.

Model G0464, G0465, G0468 Minimum

Circuit Requirement

15 Amp

Model G0467, G0470 Minimum Circuit

Requirement

20 Amp

Plug/Receptacle Type

Plug Type ..............NEMA 5-15 (Figure 1)

Figure 1. Typical type 5-15 plug and

receptacle.

This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two- pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.

Model G0464/G0465/G0467/G0468/G0470 Air Compressors

-7-

Page 9
Image 9