Grizzly G5954 Static Pressure Inch/H2O, Max CFM Max SP Volts Amps Inlet Dia Impeller Dia

Models: G5954

1 32
Download 32 pages 46.26 Kb
Page 7
Image 7

������������

�����

Customer Service #: (570) 546-9663 · To Order Call: (800) 523-4777 · Fax #: (800) 438-5901

������������������������������������������

PERFORMANCE CURVE

CFM

STATIC PRESSURE (Inch/H2O)

5 HP GRIZZLY DUST COLLECTOR PERFORMANCE RESULTS

Max CFM

 

Max SP

 

HP

 

 

Volts

Amps

Inlet Dia.

Impeller Dia.

3184

 

11.2

5

 

220

34

 

 

9"

 

13"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Restrictor Plate (Inches)

 

ø 9"

 

ø 8"

 

ø 7"

ø 6"

ø 5"

 

ø 4"

ø 3"

 

ø 2"

ø 1"

 

ø 0"

 

Static Pressure (Inch/H2O)

 

5.5

 

6.4

 

7.8

8.8

10.0

 

10.6

10.7

 

10.8

10.9

 

11.2

 

 

CFM

 

3184

 

2848

 

2415

1815

1284

 

827

617

 

503

450

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The airflow test probe is located 1.5x duct diameter upstream from the air inlet.

Test pipe length is a minimum of 10x duct diameter.

G5954 5HP Dust Collector

-5-

Page 7
Image 7