Calculating Duct Resistance
Adding duct work, elbows, branches and any other components to a duct line increases airflow resistance (static pressure loss). This resistance can be minimized by using rigid (smooth) pipe and gradual curves, as opposed to flexible pipe and 90˚ elbows.
The purpose of calculating the resistance is to determine if it is low enough from the machine to the dust collector to meet the given CFM require- ment for the machine. Use the charts in Figure 22 to calculate the resistance of duct work.
Duct | Approximate | Approximate | ||
Dia. | Static Pressure | Static Pressure | ||
| Loss Per Foot of | Loss Per Foot | ||
| Rigid Pipe | of Flex Pipe | ||
| Main | Branch | Main | Branch |
| Lines | Lines | Lines | Lines |
| at 3500 | at 4000 | at 3500 | at 4000 |
| FPM | FPM | FPM | FPM |
|
|
|
|
|
2" | .091 | .122 | .35 | .453 |
|
|
|
|
|
2.5" | .08 | .107 | .306 | .397 |
|
|
|
|
|
3" | .071 | .094 | .271 | .352 |
|
|
|
|
|
4" | .057 | .075 | .215 | .28 |
|
|
|
|
|
5" | .046 | .059 | .172 | .225 |
|
|
|
|
|
6" | .037 | .047 | .136 | .18 |
|
|
|
|
|
7" | .029 | .036 | .106 | .141 |
|
|
|
|
|
8" | .023 | .027 | .08 | .108 |
|
|
|
|
|
9" | .017 | .019 | .057 | .079 |
|
|
|
|
|
|
|
|
|
|
Fitting | 90˚ | 45˚ | 45˚ | 90˚ |
Dia. | Elbow | Elbow | Wye(Y) | Wye(Y) |
|
|
|
|
|
3" | .47 | .235 | .282 | .188 |
4" | .45 | .225 | .375 | .225 |
5" | .531 | .266 | .354 | .236 |
6" | .564 | .282 | .329 | .235 |
|
|
|
|
|
7" | .468 | .234 | .324 | .216 |
|
|
|
|
|
8" | .405 | .203 | .297 | .189 |
|
|
|
|
|
Figure 22. Static pressure loss charts.
In most small/medium shops it is only necessary to calculate the line with the longest duct length or the most fittings (operating under the assumption that if the line with the highest resistance works, the others will be fine).
G5954 5HP Dust Collector
To calculate the static pressure of any given line in the system, follow these steps:
1.Make a list of each size duct in the line, includ- ing the length, and multiply those numbers by the static pressure value given in Figure 22.
2.List each type of elbow or branch and multiply the quantity (if more than one) by the static pressure loss given in Figure 22.
3.Add any additional factors from Figure 23.
Note: Always account for a seasoned filter, so you don't end up with a system that only works right when the filter is clean.
Additional Factors | Static Pressure | |
|
| |
Seasoned (well used) | 1" | |
Dust Collection Filter | ||
| ||
|
| |
Entry Loss at Large | 2" | |
Machine Hood | ||
| ||
|
|
Figure 23. Additional static pressure factors.
4.Total your list as shown in Figure 24 to come up with your overall static pressure loss.
Note: When determining static pressure loss over multiple lines, only count the main line numbers once.
���������
��������������������������� ���������������� ����
�����������
��������������������������� ���������������� ����
������������������������ ������������������������ �����
���������������
��������������� �������������������������������� ����
������������ ���������������������������������������� ����
������������������
��������������� �������������������������������� �����
��������������������� ������������������������ �����