Grizzly G8298, G8297 Starting Pressure Regulator, G8299 starting switches and gauge

Models: G8298 G8299 G8297

1 26
Download 26 pages 5.25 Kb
Page 12
Image 12

Starting

Pressure Regulator

 

 

 

 

 

 

Make sure the compressor switch is in the OFF position (the red button on top of the control box should be in the fully depressed position, see Figure 5) before connecting to the power supply. Close the drain cock on the tanks. Pull the switch to the ON position.

On/Off

Switches

Tank

Gauge

Fig 5. G8299 starting switches and gauge.

Check the tank pressure gauge to see that the tank pressure gets up to approximately 120-130 PSI.

After the compressor has fully pressurized the tanks, turn the red knob on the pressure regula- tor (See Figure 6) to set the pressure needed for the air tool you will be using. Consult the manual which accompanied your air tool to determine what pressure setting is required for optimal oper- ation. The gauge on the regulator will indicate the pressure which will be delivered through the air line.

Fig 6. Pressure regulator and gauge.

Always wear safety glasses and use extreme caution when working around compressed air. The force of the air stream can cause small bits of debris to become airborne and cause potential injury to the eyes or other parts of the body. Never let the full force of the air stream come in direct contact with the skin as it can cause abrasions or bruising.

-10-

G8297/G8298/G8299 Air Compressors

Page 12
Image 12
Grizzly G8298, G8297 Starting Pressure Regulator, G8299 starting switches and gauge, Pressure regulator and gauge