SECTION 5: ADJUSTMENTS
! | Disconnect power to the |
machine when perform- | |
ing any adjustments on | |
| the Model G9984/G9985. |
| Failure to do this may |
| result in serious person- |
| al injury. |
Keep loose clothing rolled up and out of the way of machinery and keep hair pulled back.
Wear safety glasses during the entire adjust- ment process. Failure to comply may result in serious personal injury.
Power Switch
The Model G9984/G9985 must be turned ON to visually check the results of certain adjustments made to the sander; however, actual adjustments should never be performed while the machine is plugged in.
Figure 9. Magnetic power switch.
Dust Collection
The Model G9984/G9985 has (2) 4" dust hoods. One is positioned for use with the side table. The second dust hood is for use with the main table. The side table dust hood is adjustable to allow optimum positioning for various sanding opera- tions. To adjust the side table dust hood:
1.Loosen the lock handle shown in Figure 8.
2.Rotate the dust hood until the desired position is achieved.
3.Tighten the lock handle loosened in Step 1.
4.Hook up a 4" dust collection hose to the dust hood and secure with a hose clamp.
Dust Hood
Lock Handle
Figure 8. Dust hood lock handle.
Always wear a dust mask when using the
Model G9984/G9985. Using this machine pro- duces sawdust which may cause allergic reac- tions or respiratory problems.
G9984/G9985 Oscillating Belt Edge Sander |