Grizzly H3372 instruction manual AIR Control, Delivered Pressure Air Release

Models: H3372

1 26
Download 26 pages 26.79 Kb
Page 11
Image 11

AIR CONTROL

Delivered Pressure

 

Air Release

 

 

 

The tank pressure is displayed on the left pressure gauge, and the air to be delivered to the tool is displayed on the right pres- sure gauge shown in Figure 6.

Figure 6. Pressure gauges.

To control the air delivery to your tool:

1.Adjust the air control knob, shown in Figure 7, to set the PSI that will be delivered to your tool. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease the pressure.

Figure 7. Air control knob.

NoteÑThe air tool that you attach to the air compressor should have a preferred PSI operating level. Set the pressure to be delivered to the tool according to this pre- ferred level. Understand the duty cycle of the air compressor that is described on page 7.

H3372 3 HP Air Compressor

There are two ways to release air from the compressor tank other than through your regulator and the use of air tools:

—The drain valve. —The safety drain valve.

To release air by using the drain valve, simply turn the release nut to allow air to flow out of the tank. The drain valve is shown in Figure 5. The drain valve is also used to drain condensation that builds up in the tank.

The safety valve automatically releases pressure if the tank reaches 130 PSI.

To manually release the air in the tank by using the safety drain valve:

1.Locate the safety drain valve on the tank. The drain valve is shown below in Figure 8.

Figure 8. Safety drain valve.

2.Pull the metal ring on top of the safe- ty valve to bleed pressure from the tank. NoteÑThe ring is preset to release air if the tank exceeds its maximum pressure of 130 PSI. DO NOT try to adjust the safety valve!

-9-

Page 11
Image 11
Grizzly H3372 instruction manual AIR Control, Delivered Pressure Air Release, To control the air delivery to your tool