—If you want to increase the staple depth, then move the adjust- ing block up, toward the nose as shown in Figure 9.
Adjusting Block
Up
Figure 9. Moving the adjustment block up.
4.Tighten the depth adjustment cap screw.
5.Connect the stapler to the air supply, test the staple depth, and repeat this entire procedure if necessary until the staple depth is satisfactory.
Clearing Jammed
Staples
A jammed staple must be cleared before the stapler is used again.
To clear a jammed staple from the dis- charge area:
1.DISCONNECT STAPLER FROM THE AIR SUPPLY!
2.Unlatch the nose cover as shown in
Figure 10.
Nose Cover Latch
Figure 10. Unlatching the nose cover.
3.Open the nose cover as shown in Figure 11.
Nose Cover
Figure 11. Opening the nose cover.
4.Grab the jammed staple with a pair of pliers and remove it from the nose as shown in Figure 12.
Figure 12. Removing a jammed staple.
5.Close and latch the nose cover.
H7947/H7948 16 Gauge Stapler |