Grizzly MODEL instruction manual Model G1023S Only, 220V Operation

Models: MODEL

1 59
Download 59 pages 58.57 Kb
Page 11
Image 11
Model G1023S Only:

Model G1023S Only:

220V Operation

The Model G1023S motor is wired to operate at 220V. When operating at 220V, use a NEMA- style L6-20 plug and outlet. See Figure 7. Check the electrical codes in your area for specifics on wiring requirements.

Under normal 220V use, the motor draws approx-

 

imately 18 amps. Use a 20 amp circuit breaker or

 

a 20 amp slow-blow fuse. The circuit you use

 

should be dedicated, (i.e., the Model G1023S

 

should provide the only draw from that circuit). If

 

frequent circuit failures occur when using this

 

machine, contact our Service Department or your

 

local electrical contractor.

Figure 7. NEMA L6-20 220V plug and outlet

Because of the high amperage draw of this machine, standard household circuit wiring may not be of a large enough gauge. A qualified elec- trician must install a new circuit with wires capa- ble of handling a 18 amperage draw. Do not attempt to modify an existing circuit by replacing the circuit breaker with one rated for a higher amperage.

G1023S Series Heavy-Duty 10'' Table Saw

-9-

Page 11
Image 11
Grizzly MODEL instruction manual Model G1023S Only, 220V Operation