Scale Battery

The scale will automatically display the current scale battery voltage when you turn the scale ON and OFF. To check the voltage during use, press the MR button on the remote control and the screen will display SHIFT. Press the F1 button and the screen will display U X.XX. To return to the main display, press MR again.

When the battery voltage is lower than U 5.80, the screen will flash to alert you. The scale will continue to display for approximately one minute longer and then turn OFF automatically. The scale will need to be charged before further use.

The Model T10008 has an easy to remove battery for convenient charging. Remove the two outer cap screws from the back of the scale body. Slide the battery out and unplug the wire clip connection, as shown in Figure 6.

Figure 6. Unplugging the battery.

To recharge the battery:

1.Turn the scale OFF.

2.Connect the supplied adapter into the socket located in the back of the scale, then into a grounded 110V outlet. The light turns orange while charging and turns red when charging is complete.

Note: The battery should re-charge for at least 8 hours.

Hold Function

When the load has been added to the scale, wait until the STEADY light goes off, signifying that the load is stable (Figure 4). If you would like the weight value to remain on the screen, press the HOLD button on the remote control and the Hold LED will flash on the display (Figure 4). To clear the screen, press the HOLD button again.

Advance Tare Weight

To input a known tare weight before weigh- ing an item, press MR and the screen will display SHIFT. Press TARE, and the screen will display 00000. To input the desired weight, scroll to the right by press- ing the right arrow (TARE) button on the remote control until you come to the number that you would like to change. To increase the number from zero, press the left button () on the remote control. To submit the tare amount, press MR and the TARE light will come on the scale, automatically deducting the imputed tare weight. The tare weight will stay the same until the scale is turned OFF.

Clear Function

To clear, press the CLEAR button and the screen will flash CLr. If you would like to approve the clear command, press the MR button and the screen will display "End", and return to the main screen. If you would like to cancel the clear command, press the CLEAR button again and the display will return to the main screen.

-8-

Model T10008 2000 Kg Digital Crane Scale

Page 9
Image 9
Grizzly T10008 owner manual Scale Battery, To recharge the battery, Hold Function, Advance Tare Weight, Clear Function