High Temperature Heater Specifications

Deluxe Vane Axial Heater

HEATER INSTALLATION

High Temperature Heater Specifications

 

 

18"

24"

26"

28"

 

 

 

 

 

 

All models

Inside diameter

18.5/16"

24.1/4"

26.5/16"

28.1/8"

 

Bolt circle diameter

19.7/16"

25.3/4"

27.15/16"

29.5/8"

 

Length

22"

22.1/2"

22.1/4"

25.1/4"

 

BTU rating

1400000

2100000

2700000

3000000

 

Weight

81

110

115

140

 

 

 

 

 

 

Liquid models

Maximum fuel flow (GPH)

N/A

23

30

34

 

Orifice

N/A

3/16"

7/32"

15/64"

 

Modulating valve bypass orifice

N/A

Blue

Blue

Aluminum

 

Minimum operating pressure

N/A

2

2

2

 

Maximum operating pressure

N/A

20

20

20

 

Minimum line size

N/A

3/8"

3/8"

3/8"

 

 

 

 

 

 

Vapor models

Maximum fuel flow (CFH)

585

877

1128

1253

 

Orifice

5/32"

3/16"

7/32"

15/64"

 

Modulating valve bypass orifice

Green

Blue

Blue

Aluminum

 

Minimum operating pressure

2

2

2

2

 

Maximum operating pressure

20

20

20

20

 

Minimum line size

1/2"

3/4"

3/4"

3/4"

 

 

 

 

 

 

Natural gas

Maximum fuel flow (CFH)

1473

2210

2842

3157

models

Orifice

1/4"

5/16"

23/64"

3/8"

 

Modulating valve bypass orifice

Blue

Aluminum

Aluminum

Aluminum

 

Minimum operating pressure

1

1

1

1

 

Maximum operating pressure

7

7

7

7

 

Minimum line size

3/4"

1"

1.1/4"

1.1/4"

 

 

 

 

 

 

Low Temperature Heater Specifications

 

 

18"

24"

26"

28"

 

 

 

 

 

 

All models

Inside diameter

18.5/16"

24.1/4"

26.5/16"

28.1/8"

 

Bolt circle diameter

19.7/16"

25.3/4"

27.15/16"

29.5/8"

 

Length

22"

22.1/2"

22.1/4"

25.1/4"

 

BTU rating

400000

500000

500000

500000

 

Weight

81

110

115

140

 

 

 

 

 

 

Vapor models

Maximum fuel flow (GPH)

167

292

292

292

 

Orifice

5/64"

3/32"

3/32"

3/32"

 

Modulating valve bypass orifice

Red

Yellow

Yellow

Yellow

 

Minimum operating pressure

2

2

2

2

 

Maximum operating pressure

20

20

20

20

 

Minimum line size

3/8"

3/8"

3/8"

3/8"

 

 

 

 

 

 

Natural gas

Maximum fuel flow (CFH)

421

736

736

736

models

Orifice

9/64"

5/32"

5/32"

5/32"

 

Modulating valve bypass orifice

Yellow

Green

Green

Green

 

Minimum operating pressure

1

1

1

1

 

Maximum operating pressure

7

7

7

7

 

Minimum line size

1/2"

1/2"

1/2"

1/2"

 

 

 

 

 

 

 

 

 

 

 

 