Lighting instructions (White-Rodgers 37C)

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot that is lit by a piezo-electric spark gas ignition system. Do not open the inner door of the appliance and try to light the pilot by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some

gases are heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING AND OPERATING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Set the thermostat to lowest setting.

3.This appliance has a pilot that is lit by a spark gas ignition system. Do not try to light the pilot by hand.

4.Remove the outer burner door.

5.Push the gas control knob down slightly and turn clockwise to "OFF" (see Figure "A").

NOTE: Knob CANNOT be turned from "PILOT" to "OFF" unless it is pushed down slightly. Do not force.

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.

7.Make sure the water heater is filled with water.

8.Turn gas control knob counterclockwise to "PILOT" (see Figure "A").

9.Depress the gas control knob all the way in and IMMEDIATELY depress the

igniter button until you hear a loud click. Observe the pilot through the view port. Do not release the gas control knob. Repeat immediately if pilot does not light on the first try. If the pilot does not light by the fourth attempt with the igniter, repeat steps 5-9. Continue to hold the button for about one (1) minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If the pilot light goes out, repeat steps 5-9.

IMPORTANT: If the pilot will not stay lit after several tries, turn gas control knob to "OFF" and call your service technician or gas supplier.

IMPORTANT: If the gas control knob does not pop up to its original position when released, stop and immediately shut off the gas at the line valve or tank. Call your service technician or gas supplier.

10.Turn gas control knob counter-clockwise to "ON" (see Figure "A").

11.Once the pilot flame is established replace the outer burner door.

12.Set thermostat to desired setting.

13.If the pilot will not stay lit after several tries, turn the gas control knob clock-

wise to "OFF" (see Figure "A"). If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call a qualified service tech- nician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

Figure A

PILOT

THERMO-

COUPLE

ELECTRODE

“OFF” Position

Gas Control Knob

Top View

Gas Control Knob

Igniter

Button

Thermostat Dial

Gas Control

1.Set thermostat to the lowest setting (PILOT LIGHTING).

2.Push the gas control knob down slightly and clockwise to the “OFF” position. Do not force.

– 12 –

Page 12
Image 12
GSW 61009 REV. C (09-03) manual Lighting instructions White-Rodgers 37C, Figure a

61009 REV. C (09-03) specifications

The GSW 61009 REV. C (09-03) is a prominent model within the realm of electrical distribution and protection equipment, specifically engineered to deliver reliable performance in various industrial applications. This device is particularly tailored for low-voltage electrical networks, ensuring safety, efficiency, and longevity in operations.

One of the main features of the GSW 61009 REV. C is its advanced circuit protection capabilities. Equipped with residual current devices (RCDs), it is designed to prevent electric shocks and electrical fires, enhancing overall safety standards in any installation. The device also incorporates circuit breakers that automatically disconnect electrical circuits during overloads or short circuits, preventing potential equipment damage and safeguarding personnel.

The GSW 61009 REV. C also exhibits exceptional thermal and mechanical stability, attributed to its high-quality materials and robust engineering. It is built to withstand harsh operational environments, ensuring reliable functionality even under challenging conditions. This durability is crucial for industries such as manufacturing, construction, and energy sectors, where equipment often faces extreme temperatures and vibrations.

Technologically, the GSW 61009 REV. C is designed with user-friendly features, making installation and maintenance straightforward for technicians. It includes clear labeling and intuitive interfaces for easy operation, which simplifies the process of monitoring and troubleshooting. Furthermore, its modular design allows for easy upgrades and expansions, accommodating evolving electrical needs without the need for a complete system overhaul.

The GSW 61009 REV. C also complies with international safety standards, ensuring that it meets rigorous guidelines for electrical devices. This certification not only reinforces the product’s reliability but also builds trust with end-users aware of safety compliance in electrical installations.

Additionally, energy efficiency is a priority with the GSW 61009 REV. C, as it minimizes power loss during operation, contributing to lower energy costs. This focus on efficiency aligns with global sustainability efforts, positioning the product as a responsible choice for modern electrical applications.

In summary, the GSW 61009 REV. C (09-03) stands out as an essential component in electrical systems, offering optimal protection, durability, and efficiency. Its features and technologies make it a preferred choice for industries requiring robust and reliable electrical distribution solutions. The combination of safety, ease of use, and compliance with standards underscores its importance in safeguarding both people and infrastructure in the electrical landscape.