CAPACITY AND PERFORMANCE

 

 

 

 

 

Standard

 

 

First

 

 

Recovery Gal./Hr.

Tube Insertion

 

 

Energy

 

 

Capacity

 

Firing

BTU

 

Hour

 

 

 

Rise

Length

Combustion

Factor

Model*

 

USG (Litres)

 

Rate

Input

 

Rating

 

90OF/50OC

 

100OF/55OC

in. (cm)

Efficiency

EF

Centre Flue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JWF307

 

32 (121)

 

0.65

91,000

 

110

 

92

 

84

 

4.75 (12.1)

77-80%

 

0.60

JWF507

 

50 (189)

 

0.75

105,000

 

190

 

107

 

100

5.75 (14.6)

77-80%

 

0.55

Direct Vent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JWF307V

 

32 (121)

 

0.65

90,000

 

110

 

92

 

84

 

4.75 (12.1)

79-81%

 

0.60

ROUGH-IN DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Height

Height to Top of Heater

 

Diameter

 

Vent Diameter

Water

 

Shipping

 

 

 

 

 

A

 

 

B

 

 

C

 

D

Connection

 

Weight

Model*

 

 

in. (cm)

 

in. (cm)

 

in. (cm)

 

in. (cm)

in. (mm)

 

lb. (kg)

Centre Flue/Direct Vent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JWF307/JWF307V

 

 

52.75 (134)

50.63 (129)

 

 

20 (51)

 

6 (15)

0.75 (19)

 

172 (78)

JWF507

 

 

60.5 (154)

 

58.5 (149)

 

 

22 (56)

 

6 (15)

0.75 (19)

 

214 (97)

*Direct Vent models must use vent kit and burner supplied by John Wood® with pre-purge and post-purge features. Burners are sold separately and warranted by the burner manufacturer.

For 63 Gallon unit see pages 46 and 47 in this book.

21

Exclusive, patented innovation.

Residential Oil

Page 27
Image 27
GSW Signature Series Electric manual Capacity and Performance, ROUGH-IN Dimensions