31
CAPACITY & PERFORMANCE
|
|
|
| First Hr. Rating | Continuous |
|
|
| Capacity | Boiler Output | 900F/500C Rise | Flow | Coil Length |
| Model | USG (Litres) | BTU | USG (Litres) | USG (Litres) | in. (cm) |
| 30 (110) | 40,000 | 70 (265) | 69 (261) | 29 (74) | |
|
|
| 60,000 | 98 (371) | 104 (394) |
|
|
|
| 80,000 | 125 (473) | 139 (526) |
|
|
|
| 100,000 | 152 (575) | 173 (655) |
|
| 40 (150) | 40,000 | 84 (318) | 69 (261) | 39.5 (100) | |
|
|
|
|
|
|
|
|
|
| 60,000 | 111 (420) | 104 (394) |
|
|
|
| 80,000 | 138 (522) | 139 (526) |
|
|
|
| 100,000 | 165 (625) | 173 (655) |
|
| 75 (300) | 40,000 | 120 (454) | 70 (265) | 47.25 (120) | |
|
|
| 60,000 | 148 (560) | 105 (397) |
|
|
|
| 80,000 | 175 (662) | 140 (530) |
|
|
|
| 100,000 | 201 (761) | 174 (659) |
|
|
|
| 120,000* | 229 (867) | 209 (791) |
|
ROUGH-IN DIMENSIONS
|
|
|
|
|
|
| Height to Top of Coil Connection | Height to Top of Potable Water Connection | Height to Top of Heater | Diameter | Shipping Weight |
| A | B | C | D |
|
Model | in. (cm) | in. (cm) | in. (cm) | in. (cm) | lb. (kg) |
| 35 (89) | 34 (86) | 32 (81) | 22 (56) | 130 (59) |
| 45.5 (116) | 44 (112) | 42.5 (108) | 22 (56) | 160 (73) |
| 56 (142) | 54 (137) | 53 (135) | 26 (66) | 270 (122) |
|
|
|
|
|
|
*When the boiler input exceeds 100,000 BTU/H and if the unit has a factory supplied T&P valve, it must be replaced with one rated for that input.
Head Loss:
Exclusive, patented innovation. | Indirect Water Heaters |