Wiring the Lock to Gate Opener Control Boards

MM500/502, PRO-SW3000, PRO-SW4000

Step 1. Turn control box power switch OFF and unplug the transformer or disconnect the solar panel. Remove control box cover and disconnect battery lead wires from the battery terminals before wiring the lock board to the opener control board.

Step 2. Connect the WHITE wire (included) to Terminal #1 on the lock board. Connect the RED battery lead wire (included) to Terminal #5 on the lock board.

Step 3. Attach the RED control board battery lead wire to one spade tongue on a double spade tongue connector (included). Attach the BLACK control board battery lead wire to one spade tongue on the other double spade tongue connector (included).

Step 4. Pull RED and BLACK wires from gate lock through the strain relief and into the control box. Attach BLACK wire to Terminal #3 on lock board. Attach RED wire to Terminal #4 on lock board (see Lock Board Wiring Chart below).

Step 5. Attach RED lock board battery lead wire to the double spade tongue terminal with the RED control board lead wire. Attach the BLACK lock board battery lead wire to the double spade tongue connector with the BLACK control board Lead Wire.

Step 6. Connect the WHITE wire from the lock board directly to the MASTER OPERATOR terminal block along with the power cable wire from the opener arm. Connect the WHITE wire to the RED terminal for a Pull-to-Open installation or connect WHITE wire to the BLACK terminal for a Push-to-Open installation (see illustration on page 9).

Step 7. Reconnect opener to gate bracket. Connect the BLACK Battery lead wire (included) to Terminal #2 on the lock board. (See Lock Board Wiring Chart below). Connect RED wires (with double spade tongue terminal) to POSITIVE (+) battery terminal and the BLACK wires (with double spade tongue terminal) to the NEGATIVE (–)battery terminal. Plug the transformer in or rewire the solar and turn the control box power switch ON. Test opener and lock to make sure it functions properly and make adjustments if necessary.

Lock Board

Wiring Chart

AdjTime

Lock Board

1 2 3 4 5

WHITE Wire to

RED on OperatorTerminal

BLACK Wire To Battery

Negative (–) Terminal

*Place a dab of petroleum jelly on the terminal con- tacts to prevent corrosion.

RED Wire To Battery

Positive (+) Terminal

RED Wire From Lock

BLACK Wire From Lock

NOTE: It is recommended that the time adjustment knob is turned all the way to the right.

8

Page 9
Image 9
GTO RB909 installation manual Wiring the Lock to Gate Opener Control Boards, MM500/502, PRO-SW3000, PRO-SW4000