Guardian Technologies H2000 Inside The Body Of The Unit, Outer Surface Of The Unit, Water Tank

Models: H2000

1 5
Download 5 pages 13.81 Kb
Page 4
Image 4
INSIDE THE BODY OF THE UNIT

7. Turn the Humidity Dial to the desired

8. As soon as the Refill LED lights

volume of humidity. Toward the right and

up, turn the unit off and refill the

the humidity level increases; toward the

water tank.

left and the humidity level decreases.

 

Always unplug the unit before servicing it in any way.

The water temperature of the water remaining in the unit after use may be high.

Do not submerse the unit in the water, or allow water to enter the inside of the unit.

INSIDE THE BODY OF THE UNIT

Pour excess water out of the unit, but do not allow it to enter the spout guide. Wash out the unit with fresh water, using ONLY the cleaning brush and a soft cloth as needed.

OUTER SURFACE OF THE UNIT

Wipe the surface of the unit with a soft damp cloth if needed.

WATER TANK

If water spots remain in the water tank, wipe the inside down with a soft cloth. Do not use soap or detergents.

AIR FILTER

Gently wipe away debris from the filter with a soft cloth.

ULTRASONIC DISK

Remove spray spout (Fig. 1) and use the enclosed cleaning brush to regularly remove build up and deposits from this area (Fig. 2). Diluted white vinegar will help to prevent this build up.

**Clean the disk with the brush ONLY. No other cleaning tool should be used.

BRUSH ONLY. (Fig. 2)

E-6

Fully dry the inside and outside of the unit before storing it.

DO NOT leave water in the unit.

Store in a cool, dry place.

PROBLEM

SOLUTION

Water mist & humidity are not

Power Plug: Unplug and then try again.

produced.

Power Failure: When the power is returned, try again.

 

Tank Installation: Make sure the tank is

 

correctly attached.

 

 

Air blows but water mist is not

Excessive Water: Remove a certain amount of water

produced.

from the tank.

 

The desired humidity is lower than the current

 

temperature: Increase the desired humidity.

 

Detergent residue in tank: Wash the tank

 

out and try again.

 

 

Humidity level is low.

The surface of the ultrasonic disk is dirty: Wipe it off

 

with a soft, dry cloth. Clean with white vinegar.

 

The water in the unit is too cold: Replace with cool, but

 

not cold water.

 

Damage on the ultrasonic disk: Exchange the disk.

 

 

Warm humidity is not produced.

It may take 10-15 minutes before warm humidity

 

is created.

 

Check to see if base of unit feels warm to the touch.

 

If so warm mist is being produced.

 

 

The humidity has a bad smell.

Poor maintenance or dirty water: Clean the product

 

thoroughly, and fill it with fresh water.

 

 

White dust is forming on nearby

Hard water may deposit a certain amount of dust. Dust

furniture.

in the air also settles because of added humidity in the

 

room. Use distilled water if this becomes a nuisance.

 

Or order a Decalcification Filter (FLTDC)

 

by calling 1.866.603.5900 or

 

visiting www.guardiantechnologies.com.

 

 

 